55
Troubleshooting
RB
Short RB to COM to decelerate the motor to minimum speed
using regenerative braking. The braking rate is controlled by the
DECEL trimpot.
ENBL
Short the ENBL and COM terminals to enable the drive’s power
section. Removing the short will disable the drive and coast the
motor to a stop.
COM
Circuit common for signal switch and jumper installation
250-0281.qxd 4/4/01 11:16 AM Page 55