1
Specifications
NRGD05-D240AC-4Q
Maximum Continuous Armature Current
5.0 amps DC
Peak Armature Current*
7.5 amps DC
HP Range (120 VAC Line Voltage)
1/8 – 1/2
HP Range (240 VAC Line Voltage)
1/4 – 1
NRGD10-D240AC-4Q
Maximum Continuous Armature Current – No Heat Sink
5.0 amps DC
Maximum Continuous Armature Current with Heat Sink Installed**
10.0 amps DC
Peak Armature Current*
15 amps DC
HP Range (120 VAC Line Voltage)
1/4 – 1
HP Range (240 VAC Line Voltage)
1/2 – 2
*
Applied for less than one minute.
**
NRGD10 series drives require heat sink kit 223-0363 when continuous armature
current is above 5 ADC.
AC Line Voltage
120 VAC or 240 VAC, ±10%, 50Hz or 60 Hz, single phase
Armature Voltage Range
120 VAC line voltage
0 – 130 VDC
240 VAC line voltage
0 – 240 VDC
Form Factor
1.10
Acceleration Time Range
0.1 – 20 seconds
Deceleration Time Range
0.1 – 20 seconds
Floating Input Signal Range (signal must be isolated)
– 10 to +10 VDC
250-0281.qxd 4/4/01 11:16 AM Page 1
Содержание NRGD-4Q Series
Страница 9: ...vii Regenerative Drives Figure 1 Four Quadrant Operation...
Страница 12: ...x Notes...
Страница 15: ...3 Dimensions Figure 2 NRGD05 Series Dimensions ALL DIMENSIONS IN INCHES MILLIMETERS...
Страница 16: ...4 Dimensions Figure 3 NRGD10 Series Dimensions ALL DIMENSIONS IN INCHES MILLIMETERS...
Страница 17: ...5 Dimensions Figure 4 Heat Sink Dimensions for NRGD10 Series Drives...
Страница 33: ...21 Installation Figure 8 Regen Dump Circuit Connections To NRGD Drives...
Страница 57: ...45 Figure 15 Connection to DLC600 and PCM4 Application Notes Connection to other Minarik devices...
Страница 78: ...Notes...