16
Installation
INHIBIT switch
Shorting the INH and COM terminals on connector TB502 to
each other causes the motor to regeneratively brake the motor to a
stop at the maximum current allowed by the CURRENT LIMIT
trimpot setting, bypassing the DECEL trimpot circuit. Remove
the short to accelerate the motor to set speed.
An alternative is to install a single-pole, single- throw switch
between the INH and COM terminals. Close the switch to
decelerate to a stop. Open the switch to accelerate the motor to set
speed.
250-0281.qxd 4/4/01 11:16 AM Page 16