54
Troubleshooting
Terminal assignments
S0
Circuit common for 10K ohm speed adjust potentiometer or
isolated voltage input signal.
S1
Fl10 VDC reference for 10K ohm speed adjust
potentiometer.
S2
Accepts a 10K ohm speed adjust potentiometer wiper or isolated
–10 VDC to +10 VDC reference.
S3
Floating –10 VDC reference for 10K ohm speed adjust
potentiometer.
DIR
Short the DIR and COM terminals to reverse the direction of
motor shaft rotation.
INHIBIT
Short the INHIBIT and COM terminals to brake the motor to a
stop at a rate controlled by the CURRENT LIMIT trimpot,
bypassing the DECEL trimpot circuit.