Installation
Optional switch connections
Connect the following switches or jumpers to terminal board
TB502 as shown in Figure 6, page 17.
ENABLE/DISABLE switch
Install a single-pole, single-throw switch between the ENABLE
and COM terminals. Open the switch to disable the drive and
coast the motor to a stop. Close the switch to enable the drive
and run the motor. If no switch is installed, a jumper must be
installed for the drive to run.
RUN/BRAKE switch
Install a single-pole, single-throw switch between the RB and
COM terminals. Close the switch to regeneratively brake the
motor to minimum speed at a rate controlled by the DECEL
trimpot. Open the switch to accelerate the motor to set speed at a
rate controlled by the ACCEL trimpot.
Direction switch
Install a single-pole, single-throw switch between the DIR and
COM terminals. Close the switch to change direction. Refer to
the Application Notes for additional direction switch connections.