6-17
1
1
1
1
Tr
oubleshooting
6
Problems Causing an Error Display
Display
Cause
Remedy
ERROR C36
MARKdetect
No registration mark was detected.
Make sure workpiece is not floating
Check to see if the starting point to
detect the registration mark has
been set properly. (
Check to see if the black
registration mark is printed against
the white background.
Check to see if there is no dust or
dirt between the registration marks.
Check to see if there is no mistake
in
registration
mark
settings.
(
Set the “MARK FILL UP” of
registration mark detection to “ON”
when
filled
in
around
the
registration mark.
(
Make sure the height of the sensor
is correct. (
Confirm the status and the settings
described above. If still no
registration mark is detected,
contact your distributor or a sales
office of MIMAKI.
ERROR C37
MARK ORG
The origin point was detected
outside the cutting area.
Arrange the registration marks
inside the sheet.
ERROR C38
MARK SCALE
Registration mark detection was not
achieved. However, this error is
attributable to a false detection or a
compensation value setting error,
since the calculated compensation
value is wrong.
Correct the compensation value if it
is wrong, and perform detection
again.
The required scale compensation
value was not smaller than 1.3
times or not greater than 0.7 times.
Remove the cause of the detection
error, for example, correct the
blurred print of registration mark
data and then retry.
A detection error occurred since the
distance from the adjacent graphics
was too short.
Increase the distance from the
adjacent graphics properly, and
perform printing again.
The designateed spacing between
the registration marks is not correct.
The value of the spacing between
the registration marks designated
by the command is wrong and it is
attributable to a selection error of
data. Therefore, check the output
data.
The print is not uniform and some
graphics are omitted.
Correct the graphic data to obtain
uniform print and perform printing
again.
As the printed registration mark was
blurred, it was not read correctly
and the registration mark of the next
graphics was read by mistake.
Perform printing again with care
that the print is not blurred.
Содержание CFL-605RT
Страница 7: ...vi ...
Страница 14: ...xiii ...
Страница 48: ...2 8 1 Put the workpiece on the cutting panel 2 Press ...
Страница 68: ...2 28 ...
Страница 138: ...4 22 ...
Страница 168: ...6 24 ...
Страница 169: ...D202786 14 30062016 ...
Страница 170: ...TM FW 1 5 MIMAKI ENGINEERING CO LTD 2016 ...