6-16
Problems Causing an Error Display
A message appears on the screen when an abnormality occurs in this unit.
Take the appropriate remedy for the displayed message.
Non-fatal Errors
Display
Cause
Remedy
ERROR C02
MAIN RAM
Trouble has occurred in the control
RAM.
Contact your dealer or a sales office
of MIMAKI.
ERROR C04
EEPROM
Trouble has occurred in the system
ROM.
ERROR C10
COMMAND
Code other than command data has
been received.
Check the command setting on the
host computer.
ERROR C11
PARAMETER
A parameter outside the numerical
range has been received.
Check the parameter.
ERROR C12
DEVICE
The plotter received an improper
device control command.
Check the command setting on the
host computer.
ERROR C13
PM OVER
Data on polygon has overflown the
polygon buffer.
Change the setting so that the
polygon command is not used.
ERROR C20
I/O
The communication condition is
different.
Make the communication
condition same as that of the host
computer side.
(
ERROR C27
BUFFERover
The interface is faulty.
Check the interface cable.
ERROR 901
OPERATION
An invalid operation was performed
on the control panel.
Refer to the relevant page of
operation
manual
for
valid
operations.
An ASCII dump was made with an
effective area less than A3.
Set the effective area to at least A3
size before conducting an ASCII
dump.
An ASCII dump was made with the
origin set at a position that does not
allow an effective area of A3 to be
obtained.
ERROR C31
NO DATA
The plotter started the plural sheets
cutting but found that there is no
data in the receiver buffer.
Refer to the explanation of the
plural sheets cutting function.
(
ERROR C32
DATAtooBIG
Received data is too large, it is not
possible to cut the number of copies
ERROR 902
DAT REMAIN
The plotter executed an improper
operation during a halt.
Press the
key to cut the
remaining data or execute data
clear if there is no need of using the
data in the receiver buffer.
(
Содержание CFL-605RT
Страница 7: ...vi ...
Страница 14: ...xiii ...
Страница 48: ...2 8 1 Put the workpiece on the cutting panel 2 Press ...
Страница 68: ...2 28 ...
Страница 138: ...4 22 ...
Страница 168: ...6 24 ...
Страница 169: ...D202786 14 30062016 ...
Страница 170: ...TM FW 1 5 MIMAKI ENGINEERING CO LTD 2016 ...