Tank dimensions 'A' and 'L' are entered via parameters P052 and P053 respectively.
P051 Max Volume
For Readings in volumetric units (rather than percent), enter the vessel volume between
Empty (P006) and Span (P007).
The units of measurement for this reading are non-dimensional. The volume is calculated
from the empty position to the maximum position and is scaled according to the Tank
Shape (P050) value. This enables the use of any volume units required.
Example
If max. volume = 3650 m
3
, enter 3650.
If max. volume = 267500 gallons, enter 2675 (100's of gallons).
Enter the volume of the tank at full (Factory = 1)
3 = parabolic bottom
4 = spheric bottom
5 = angled bottom
6 = flat ends
7 = parabolic ends
8 = sphere
Notes:
•
Maximum volume entered not to exceed 30,000.
•
OCM calculation is an optional feature. MiniRangers with the OCM feature
have this icon on the front:
.
A
A
A
A
L