![Milltronics miniranger plus Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/milltronics/miniranger-plus/miniranger-plus_instruction-manual_1796962018.webp)
Page 14
MiniRanger Plus – INSTRUCTION MANUAL
7ML19981CJ02
Synchronization
In applications where more than one MiniRanger Plus, to a maximum of 8, are going to be
used or where their transducers are sharing a common conduit, synchronization is
required. When synchronized, no device transmits within 180 ms of the prior one(s).
To synchronize, interconnect the SYNC terminals of all devices and ensure that there is a
common electrical ground interconnecting all units.
To synchronize MiniRanger Plus with other Siemens Milltronics products, consult
Siemens Milltronics or your distributor.
Wall Mount
Rack and Panel Mount
SYNC
SYNC
TB1
TB1
+
+
mA
BLK
BLK
mA
MiniRanger Plus #1
MiniRanger Plus #2
to next device
A6
A8
C8
A10
C10
A12
C12
A14
C14
C16
A6
A8
C8
A10
C10
A12
C12
A14
C14
C16
MiniRanger Plus #1
MiniRanger Plus #2
to next device