Door does not close correctly
1. Incorrectly fitted Stopper at end of Top Basket Guide.
a. Remove the Stopper and fit it correctly.
2. Door Seal incorrectly fitted and protrudes forward.
a. Remove the Door Seal and fit it correctly (5.3.1).
3. Damaged Door Hinges
a. Inspect and replace Hinges as necessary (5.2.5).
4. Locking latch is in the wrong position (Integrated models)
a. Press door lock release.
5. Locking bolt is in the wrong position (Fully Integrated models)
a. Activate the door lock emergency release (5.2.13).
6.8.8
Condensation forms on adjacent cabinets
During the drying cycle, condensation may form on the cabinets to the left and right
of the dishwasher.
1. Extraneous air is sucked in the area of the condenser.
a. Remove right side panel (5.1.1).
b. Seal the opening behind the rib of the condenser with silicone
sealer (for example Thermostat) see Fig. 6-1.
2. Modify the dishwasher with conversion kit “Vapors VI”
Note
In dishwashers starting with production number 33/65009505 the opening
at the condenser pocket is already closed.