Technical Information
114
G1000 / G2000 Dishwashers
Control
Dial
Position
Function Programming
Display
Flashing Rhythm of
Rinse LED
Long Short Display
- - U0
- 1 U1
- 2 U2
- 3 U3
- 4 U4
- 5 U5
- 6 U6
- 7 U7
- 8 U8
- 9 U9
1 0 U10
1 1 U11
1 2 U12
1 3 U13
3 o’clock
Component
test
Turn the control dial
to the 3 o’clock
position. To start
the component test,
or to access the
next component to
be tested, press the
Start/Stop button.
The flashing rhythm
of the Rinse LED
indicates which
component test is
activated. For the
sequence of
component testing
as well as
background
information and
access procedure,
refer to the
component test
information. Ref. to
6.2.1.3 For further
information.
1 4 U14
Long Short Display
5 o’clock
Operating
hours
Turn the control dial
to the 5 o’clock
position. To check
for operating hours,
press the Start/Stop
button.
The flashing rhythm
of the Rinse LED
shows the
registered
operating hours:
Each long flash
corresponds to
1000 hours and
each short flash
100 hours.
- - -
Long Short Display
6 o’clock
LED test
Turn the control dial
to the 6 o’clock
position. To start
the control panel
test, press the
Start/Stop button.
All LEDs are lit.
- - -
Table 6-8:
G2020 Service Mode Options (continued from Table 6-7)
Save and quit
Switch off the unit.
Содержание Advanta G2020SC
Страница 1: ...Technical Information G1000 G2000 Dishwashers TECHNICAL INFORMATION G1000 G2000 Dishwashers 1 ...
Страница 33: ...Technical Information G1000 G2000 Dishwashers Figure 4 4 Water Inlet Mixer 33 ...
Страница 73: ...Technical Information 73 G1000 G2000 Dishwashers 5 3 Inner Cabinet 5 3 1 Door Seal Replacement ...
Страница 103: ...Technical Information G1000 G2000 Dishwashers 5 5 Electronic Unit Figure 5 39 Electronic Integrated Model 103 ...