Technical Information
218
G1000 / G2000 Dishwashers
Figure 6-8:
Circuit test path for
F-51
(testing state)
1. Check the Heater relay for an open contact. If the relay is open during the testing
state, Fig. 6-8. Then perform the following checks:
a. Check to insure all plug connections are clean and secure.
b. Check the connection wires for continuity.
•
If the Heater relay still shows an open contact, replace the Heater relay.
2. Insure the Heater pressure switch is in position 21/22 and 11/12. If not, perform
the following checks:
a. Check to insure all plug connections are clean and secure.
b. Check the connection wires for continuity.
c. Remove the Heater pressure switch and check for any blockage
•
If the Heater pressure switch still shows an open circuit. Replace the
Heater pressure switch.
If a F68 fault is displayed
The speed sensor registers that the circulation pump is still operating even after it
has been switched off.
1. Check connectors to circulation pump speed sensor and electronic board.
2. Perform a continuity check to insure there is no open circuit.
3. Replace the speed sensor and perform an operational check.
•
If the fault is again displayed, replace the electronic board.
Содержание Advanta G2020SC
Страница 1: ...Technical Information G1000 G2000 Dishwashers TECHNICAL INFORMATION G1000 G2000 Dishwashers 1 ...
Страница 33: ...Technical Information G1000 G2000 Dishwashers Figure 4 4 Water Inlet Mixer 33 ...
Страница 73: ...Technical Information 73 G1000 G2000 Dishwashers 5 3 Inner Cabinet 5 3 1 Door Seal Replacement ...
Страница 103: ...Technical Information G1000 G2000 Dishwashers 5 5 Electronic Unit Figure 5 39 Electronic Integrated Model 103 ...