Technical Information
176
G1000 / G2000 Dishwashers
Function Programming
Display
Pos. 20:
Resetting
standard
settings
Use the cursor buttons as
appropriate to select
Factory
default,
then press the
OK
button.
Use the cursor buttons to make the
desired setting.
The display shows the option
Reset.
If it is selected, all
parameters that can be
modified by the customer
(extras and settings) will be
reset to the standard settings.
Pos. 21:
Wash/Final
rinse
temperature
modification
(from software
version ID no.
984).
Use the cursor buttons as
appropriate to select
Temperatures,
then press the
OK
button. Use the cursor buttons to
make the desired setting.
The display shows the options
Main wash
and
Final rinse.
This increases the main wash
or final rinse temperature with a
running time extension.
Main wash
Use the cursor buttons to select the
desired option.
The display shows the options
Normal
and
Increased
Final rinse
Use the cursor buttons to select the
desired option.
The display shows the options
Normal
and
Increased
Pos. 23: Water
quantity normal
/ increased
Use the cursor buttons as
appropriate to select
Water plus,
then press the
OK
button. Use the
cursor buttons to make the desired
setting.
The display shows the options
Normal
and
Increased
Automatic
= sensor softener
activated. Alternatively the on-
site water hardness can be
directly selected. Setting range:
1°d to 70°d (°d = Degree of
German hardness). See Table
6-2.
Pos. 24:
Sensor
softener
activation /
deactivation,
water hardness
manual setting
Use the cursor buttons as
appropriate to select
Water
hardness,
then press the
OK
button. Use the cursor buttons to
make the desired setting.
Pos. 25:
Program
running time
reduction (from
software
version ID no.
984)
Use the cursor buttons as
appropriate to select
Shorten the
program,
then press the
OK
button. Use the cursor buttons to
make the desired setting.
The display shows the options
On
and
Off
(standard setting).
This offers a program-
dependent running time
reduction by reducing
temperatures and/or canceling
holding times.
Pos. 26:
Second interim
rinse selection
(from software
version ID no.
984)
Use the cursor buttons as
appropriate to select
2
nd
interim
rinse,
then press the
OK
button.
Use the cursor buttons to make the
desired setting.
The display shows the options
On
and
Off
(standard setting)
Table 6-47:
G2630 Programming Mode Options (Cont. From Table 6-46) (Cont. on Table 6-48)
Содержание Advanta G2020SC
Страница 1: ...Technical Information G1000 G2000 Dishwashers TECHNICAL INFORMATION G1000 G2000 Dishwashers 1 ...
Страница 33: ...Technical Information G1000 G2000 Dishwashers Figure 4 4 Water Inlet Mixer 33 ...
Страница 73: ...Technical Information 73 G1000 G2000 Dishwashers 5 3 Inner Cabinet 5 3 1 Door Seal Replacement ...
Страница 103: ...Technical Information G1000 G2000 Dishwashers 5 5 Electronic Unit Figure 5 39 Electronic Integrated Model 103 ...