Technical Information
136
G1000 / G2000 Dishwashers
Flashing
Rhythm of
Intake/Drain
Lt.
Function Programming
Display
Flashing Rhythm of
Rinse LED
Long Short
Long Short Display
- - U0
- 1 U1
- 2 U2
- 3 U3
- 4 U4
- 5 U5
- 6 U6
- 7 U7
- 8 U8
- 9 U9
- 2
Pos.2:
Component
test
Press the Program
button 2 times. The
Rinse & Hold LED
flashes 2 times
rapidly
intermittently. Press
the Start/Stop
button. Press it
again to activate the
next component.
The Rinse LED
shows which
component is being
tested: For example
if the drain pump
M8 is being tested,
the Rinse LED
flashes 3x briefly
intermittently. For
the test sequence
and background
information about
individual
components and
their activation, see
6.3.1.3, Component
test.
1 0 U10
1 1 U11
1 2 U12
1 3 U13
1 4 U14
Long Short
Long Short Display
- 3
Pos 4:
Operating
hours
check
Press the Program
button 3 times. The
Rinse & Hold LED
flashes 3 times
rapidly
intermittently.
The Rinse LED
shows the number
of operating hours
as follows: If the
machine has run for
74 hours, the Rinse
LED flashes 7x
long and 4x briefly
intermittently.
- - -
Long Short
Long Short Display
- 4
Pos. 5:
LED test
Press the Program
button 4 times. The
Rinse & Hold LED
flashes 4 times
rapidly
intermittently. Press
the Start/Stop
button once.
All LEDs are lit.
- - -
Table 6-22:
G2140 Service Mode Options (Continued from Table 6-21)
Save and quit
Switch off the unit.
Содержание Advanta G2020SC
Страница 1: ...Technical Information G1000 G2000 Dishwashers TECHNICAL INFORMATION G1000 G2000 Dishwashers 1 ...
Страница 33: ...Technical Information G1000 G2000 Dishwashers Figure 4 4 Water Inlet Mixer 33 ...
Страница 73: ...Technical Information 73 G1000 G2000 Dishwashers 5 3 Inner Cabinet 5 3 1 Door Seal Replacement ...
Страница 103: ...Technical Information G1000 G2000 Dishwashers 5 5 Electronic Unit Figure 5 39 Electronic Integrated Model 103 ...