Technical Information
130
G1000 / G2000 Dishwashers
Flashing
Rhythm of
Intake/Drain
Lt.
Flashing Rhythm of
Sani-Wash Lt.
Function Programming
Display
Long Short
Long Short Display
- -
Pos. 0:
Software
version ID
check
Do not press the
Program
button.
The
Rinse & Hold
LED is off.
The Rinse LED is off
or flashes. Shows
the software version
ID No., e.g. –769.
- -
ID
No.
Long Short
Long Short Display
- - P0
Press the
Program
button
once. The
Rinse
& Hold
LED
flashes once
rapidly
intermittently.
Press the
Start/Stop
button
to reset all
standard settings.
Pos. 1:
Reset
The Rinse LED is off
or flashes. This
programmable
function can be used
to reset all
modifiable
parameters (both
customer and
service
programming) to the
standard settings.
The display shows P
and a digit
alternately: P0 =
Non-standard
settings have been
made; P1 = All
settings reset to
standard settings or
no modifications
have been made
.
- 1
- 1 P1
Long Short
Long Short Display
-
0
P0 (0 ml)
1
1
P1 (1 ml)
2 2
P2
(2ml)
3
3
P3 (3 ml)
4
4
P4 (4 ml)
The Rinse LED is off
or flashes: P3
(standard setting)
indicates a
dispensed quantity
of 3 ml. Setting
range: 0 ml – 6 ml.
Pos 3:
Dispensed
rinse aid
quantity
setting
5
5
P5 (5 ml)
Press the
Program
button 3
times. The
Rinse
& Hold
LED
flashes 3 times
rapidly
intermittently.
Press the
Start/Stop
button
as appropriate to
make the desired
setting.
- 3
6 6
P6
(6ml)
Table 6-17:
G2140 Program Mode Options (Continued on Table 6-18)
Содержание Advanta G2020SC
Страница 1: ...Technical Information G1000 G2000 Dishwashers TECHNICAL INFORMATION G1000 G2000 Dishwashers 1 ...
Страница 33: ...Technical Information G1000 G2000 Dishwashers Figure 4 4 Water Inlet Mixer 33 ...
Страница 73: ...Technical Information 73 G1000 G2000 Dishwashers 5 3 Inner Cabinet 5 3 1 Door Seal Replacement ...
Страница 103: ...Technical Information G1000 G2000 Dishwashers 5 5 Electronic Unit Figure 5 39 Electronic Integrated Model 103 ...