Technical Information
142
G1000 / G2000 Dishwashers
Flashing
Rhythm of
Intake/Drain
Lt.
Function Programming
Indication
Flashing Rhythm of
SaniWash LED
Long Short
Long Short Display
- - P0
1 2
Pos. 12:
Reset to
factory
setting
Press the
Program
button
12x
To reset all
parameters to
factory setting,
press the
Program
button
and hold it until
the
Intake/Drain
LED flashes.
Then press the
Program
button
to enter the
desired setting
changes. *2
The
Intake/Drain
LED flashes 1x long
and 2x briefly
intermittently. With
this programming
function, all
parameters that can
be modified by the
customer can be
reset to the factory
setting.
If the
SaniWash
LED
is off, the values are
not at the factory
setting. If the
SaniWash
LED
flashes, all values
correspond to the
factory setting.
- 1 P1
Long Short
Long Short Display
-
- P0
2 -
Pos. 20: Set
the wash
temperature
Press the
Program
button
20x
To change the
setting, press the
Program
button
and hold it until
the
Intake/Drain
LED flashes.
Then press the
Program
button
to enter the
desired setting
changes. *2
The
Intake/Drain
LED flashes 2x long
intermittently.
The
SaniWash
LED
is off = normal wash
temperature; the
SaniWash
flashes =
increased wash
temperature with a
resulting running time
extension.
- 1 P1
Table 6-25:
G1180 / G2180 Programming Mode Options (Cont. from Table 6-24) (Cont. on Table 6-26)
Содержание Advanta G2020SC
Страница 1: ...Technical Information G1000 G2000 Dishwashers TECHNICAL INFORMATION G1000 G2000 Dishwashers 1 ...
Страница 33: ...Technical Information G1000 G2000 Dishwashers Figure 4 4 Water Inlet Mixer 33 ...
Страница 73: ...Technical Information 73 G1000 G2000 Dishwashers 5 3 Inner Cabinet 5 3 1 Door Seal Replacement ...
Страница 103: ...Technical Information G1000 G2000 Dishwashers 5 5 Electronic Unit Figure 5 39 Electronic Integrated Model 103 ...