Technical Information
G1000 / G2000 Dishwashers
Flashing
Rhythm of
Intake/Drain
Lt.
Flashing Rhythm of
SaniWash LED
Function Programming
Indication
Long Short
Long Short Display
The
Intake/Drain
LED flashes 2x long
and 2x briefly
intermittently.
Press the
Program
button
22x
- - P0
Pos. 22:
Program
running time
reduction
2 2
To change the
setting, press the
Program
button
and hold it until
the
Intake/Drain
LED flashes.
Then press the
Program
button
to enter the
desired setting
changes. *2
The
SaniWash
LED
is off = normal
program cycle
(factory setting); the
SaniWash
LED
flashes = shortened
program cycle.
Reduction in running
time due to a
decrease in
temperature and/or
the removal of hold
times.
- 1 P1
Long Short
Long Short Display
Press the
Program
button
23x.
The
Intake/Drain
LED flashes 2x long
and 3x briefly
intermittently.
- - P0
2 3
Pos. 23:
Water
quantity
normal /
increased
To change the
setting, press the
Program
button
and hold it until
the
Intake/Drain
LED flashes.
Then press the
Program
button
to enter the
desired setting
changes. *2
The
SaniWash
LED
is off = normal water
volume (factory
setting); the
SaniWash
LED
flashes = increased
water volume.
- 1 P1
Table 6-26:
G1180 / G2180 Programming Mode Options (Cont. from Table 6-25) (Cont. on Table 6-27)
143
Содержание Advanta G2020SC
Страница 1: ...Technical Information G1000 G2000 Dishwashers TECHNICAL INFORMATION G1000 G2000 Dishwashers 1 ...
Страница 33: ...Technical Information G1000 G2000 Dishwashers Figure 4 4 Water Inlet Mixer 33 ...
Страница 73: ...Technical Information 73 G1000 G2000 Dishwashers 5 3 Inner Cabinet 5 3 1 Door Seal Replacement ...
Страница 103: ...Technical Information G1000 G2000 Dishwashers 5 5 Electronic Unit Figure 5 39 Electronic Integrated Model 103 ...