Technical Information
G1000 / G2000 Dishwashers
5.4.6
Bottom Spray Arm Removal
1. Remove the bottom basket.
2. Remove the spray arm.
5.4.7
Feed Pipe with Turbidity Sensor – Top Spray Arm, Removal
1. Remove the right side panel; see Side panel removal ( 5.1.1).
2. Disconnect the turbidity sensor plug connections.
3. Top spray arm removal (5.4.4).
4. Unscrew the counter nut.
5. Drip pan removal (5.1.2).
6. Disconnect the hose clip connection to the circulation pump.
5.4.8
Feed Pipe – Middle Spray Arm, Removal
1. Remove the right side panel. See Side panel removal (5.1.1).
2. Remove the top basket.
3. Dismantle the feed pipe on the rear panel inside the cabinet.
Note
To release the feed pipe in the rear panel through-feed area, hold the
stub at the rear and pull it while at the same time pushing in the seal
from the inside with a suitable screwdriver to reduce its cross-sectional
area.
4. Drip pan removal, (5.1.2).
5. Remove the right multi-plinth, see Multi-plinth removal, (5.3.5).
6. Disconnect the hose clip connection to the circulation pump.
5.4.9
Spray Arm Sensor Removal
1. Remove the right side panel; see Side panel removal, (5.1.1).
85