Chapter 1 Overview
Configuration Management
Frequency and Timing Outputs
The SyncServer S6x0 can provide NTP,10 / 5 / 1 MHz, 1PPS, IRIG, or TOD output
signals. The NTP signals use the RJ45 (1 - 4) connectors on the rear panel. The
serial TOD output connects to a DB9 connector (DATA/SERIAL) on the rear panel.
The IRIG B, PPS, 10 MPPS, and 10 / 5 / 1 MHz signals use BNC connectors (J3 -
J8) on the Timing I/O module on the rear panel. A 1PPS output is also available
using a BNC connector (1PPS) on the rear panel.
Configuration Management
The SyncServer S6x0 can be configured using the keypad interface, web interface
or Command Line Interface.
Keypad/Display Interface
The keypad/display interface displays the time, system status, and provides the
following functions:
Configuring and enabling/disabling the LAN1 network port
Setting the time and entering freerun mode
Adjusting the brightness
Locking the keypad
Shutting down the SyncServer
Table 1-1. Timing Input/Output Module
Config.
Input BNCs
Output BNCs
J1
J2
J3
J4
J5
J6
J7
J8
Standard
IRIG B AM
124 or 1PPS
10 MHz
IRIG B AM
10 MHz
IRIG B B004
DCLS
1PPS
off
off
Flex Port
Option
IRIG B124
IRIG B004
IRIG B120
IRIG B000
IEEE 1344
1PPS
10 MPPS
1 MHz
5 MHz
10 MHz
FlexPort J3-J8 Software Selectable Outputs per BNC (Configured via
the web interface):
a) Pulse:
i) Fixed Rate: 10/5/1MPPS, 100/10/1/kPPS, 100/10/1/0.5PPS
ii) Programmable Period: 100 ns to 2 sec, step size of 10 ns
b) Timecode: IRIG B 000/004/1344 DCLS, 120/124/1344 AM
c) Sine: 1/5/10 MHz