120
SyncServer 600 Series User’s Guide
098-00720-000 Revision B – April, 2016
Chapter 5
SyncServer S6x0 CLI Command Set
8
Secondary
Power
Dual AC version
“–” = OK
“w” = Fault
Single AC version
“–” = OK
This alarm can only be set for the
version that has Dual AC.
9
Rb Oscillator
Unit with Rb
“–” = OK
“R” = Fault
Unit without Rb
“–” = OK
The Rubidium Oscillator indicator
reports “OK” when the Rubidium
Oscillator is operating normally. It
reports “Fault” when the Rubidium
Oscillator is warming up or has a PLL
fault.
Faults that occur during the warm up
period after the unit is started up are not
significant. This is normal behavior as
the oscillator must perform an initial
transition from unlocked to locked.
This alarm can only set on a unit that
contains an Rb oscillator.
A
Excessive
Frequency
Adjustment
“–” = OK
“X” = Fault
“X” is indicated when the “Excessive
Frequency Adjustment” alarm is set.
B
Clock Status -
First time lock
“–” = First time lock OK
“A” = Clock Status has
not locked since power
on
“A”is indicated until the “First
normal-track since power up” transient
alarm has occurred. Thereafter it
remains “–”.
C
Time Error
“–” = OK
“U” = Fault
“U” is indicated when the “Holdover time
error threshold exceeded” condition is
set. The severity setting has no impact.
The condition for what will set this alarm
is defined on the WebGUI Dashboard >
Timing > Holdover form.
D
Timeout
Always “–”
E
NTP
Always “–”
F
IRIG - Slot B
“–” = OK
Always “–”
G
External Input
Reference -
Slot B
“–” = OK
Always “–”
H
(For future use)
“–” = OK
Always “–”
I
(For future use)
“–” = OK
Always “–”
Table 5-3. F73 Alarm Indicators
Syntax
Alarm
Indicators
Description