146
SyncServer 600 Series User’s Guide
098-00720-000 Revision B – April, 2016
Chapter 6 Provisioning
Provisioning Input References
Provisioning Sine Wave Inputs on Timing I/O Module
Sine wave inputs are available for Port J2 of the Timing I/O module with the
SyncServer S650.
Table 6-7. Configure IRIG or Pulse Inputs on Timing I/O Module
Method
Steps
Notes
Web Interface
Option Slot A > Timing I/O Card
1. In the section of the form labeled
“J1 Input”, use dropdown box to
select the input signal category of
interest: Timecode, “Pulse”, or Off.
2. For TimeCode, use the dropdown
box to select the type of IRIG
input:
- B000 - DCLS
- B004 - DCLS
- B120 - AM
- B124 - AM
- B1344 - AM
- B1344 - DCLS
3. For Pulse, use the dropdown box
to select 1PPS or 10MPPS.
4. Click the
Apply
button.
CLI
n/a
n/a
Front Panel
n/a
n/a
Note:
A Flex Port Option license is required for full configurability of
all BNC connectors on the Timing I/O module.