![Microsemi SyncServer S600 Скачать руководство пользователя страница 145](http://html1.mh-extra.com/html/microsemi/syncserver-s600/syncserver-s600_user-manual_1788481145.webp)
098-00720-000 Revision B – April, 2016
SyncServer 600 Series User’s Guide
143
Chapter 6 Provisioning
Provisioning the Ethernet Ports
Note:
If using a gateway, then all IP interfaces should be configured
with the proper gateway IP address and subnet mask. If not using a
gateway, then configure the SyncServer S6x0 to not use a gateway by
setting the gateway address to 0.0.0.0. If a gateway address is
programmed on LAN1, then the gateway/router must be present and
reachable for the port to operate normally.
Table 6-5. Setting Ethernet Port Parameters
Method
Steps
Notes
Web Interface
Network > Ethernet
1. Select the speed with Speed dropdown
box for the desired port
2. Select the IP address type by clicking
on the IPv4 check box
3. Enter the IP address using the
dot-decimal notation format
xxx.xxx.xxx.xxx
4. Enter the Subnet mask using the
dot-decimal notation format
xxx.xxx.xxx.xxx. For IPv6, enter the
prefix length.
5. Enter the Gateway address using the
dot-decimal notation format
xxx.xxx.xxx.xxx.
6. Click the
Apply
button.
CLI
set ip ip-address lan {1|2|3|4} ipv4
address <addrv4_value> netmask
<maskv4_value> gateway
<gatewayv4_value>
set ip address-mode lan{1|2|3|4}
{ipv4|ipv6} dhcp
Front Panel
Menu button
Select “1) LAN1”
Select “1. Configure”
Select “1) IPv4” or “2) IPv6 (DHCPv6)
If IPv4, select Addressing Type “1) Static
Addr” or “2) DHCP”
If IPv4 Static Addr,
enter IPv4 address and press Enter
button
enter netmask and press Enter button
enter gateway and press Enter button
Can only be used to
set parameters for
LAN1.