156
SyncServer 600 Series User’s Guide
098-00720-000 Revision B – April, 2016
Chapter 6 Provisioning
Provisioning Alarms
Provisioning IRIG Outputs on Timing I/O Module
The standard configuration offers a broad yet fixed selection of signal I/O. J1 is
dedicated to time code and rate inputs, J2 to sine wave inputs, and J3-J8 to mixed
signal outputs. See
for the standard Timing I/O Module configuration.
The FlexPort™ Technology option enables the 6 output BNCs (J3-J8) to output any
supported signal (time codes, sine waves, programmable rates, etc.) on all
configurable ports via the secure web interface..
Provisioning Alarms
This section describes the controls used to provision and manage alarms in the
SyncServer S6x0. For a list of all alarms, see
.
Table 6-15. Configure IRIG and Other Outputs on Timing I/O Module
Method
Steps
Notes
Web Interface
Option Slot A > Timing I/O Card
1. For desired output J3-J8, use
dropdown box to select the
general signal output type of
“Pulse”, “Timecode” “Sine” or Off.
2. For TimeCode, use the dropdown
box to select the type of IRIG:
- B000 - DCLS
- B004 - DCLS
- B120 - AM
- B124 - AM
- B1344 - AM
- B1344 - DCLS
3. For Pulse, use the dropdown box
to select Fixed Rate or
Programmable Period.
4. For Pulse, use the dropdown box
to select the rate or period.
5. Click the
Apply
button.
CLI
n/a
n/a
Front Panel
n/a
n/a