SyncServer 600 Series User’s Guide
098-00720-000 Revision B – April, 2016
Appendix B Specifications and Factory Defaults
Factory Defaults
Timing
References
Table B-26. Timing > Holdover Configuration Parameters
Description
Default Value
Value Range
Time Error Limit
Computed from
Holdover
Duration default,
result depends
on oscillator type.
0.000100 ms to 100 ms
Holdover Duration
1 day
0.001 days to 200.00 days
Table B-27. Timing > Serial Parameters
Description
Default Value
Value Range
Output
Off
Off | NMEA | NENA | Legacy
NMEA Detail
All Off
Any combination of the following
allowed: ZDA on/off, GGA on/off, GSV
on/off, RMV on/off
NENA Detail
DDD…
DDD… | WWW … | YYYY …
Table B-28. References > GNSS Configuration Parameters
Description
Default Value
Value Range
Elevation Mask
5
5 to 60 degrees
Step size is 1 deg
Mode
Survey
Survey | Position Hold