Quadrus EZ Reader User’s Manual
3-13
Read Cycle
Serial Trigger
Serial Trigger Character (delimited)
Note:
Serial Data or Serial Data or Edge triggering mode must be enabled for Serial
Trigger Character to take effect.
Start and Stop Trigger Characters (non-delimited)
Usage:
Allows the user to define the trigger character and delimiters that start and
stop the read cycle.
Definition:
A serial trigger is considered an online host command and requires the
same command format as all host commands: that is, to be entered within
angle brackets delimiters
< >
or in the case of non-delimited triggers, define
individual start and stop characters.
Usage:
Allows the user to define the trigger character that initiates the read cycle.
Definition:
A single ASCII host serial trigger character that initiates the read cycle.
A delimited trigger character is one that either starts or ends the read cycle
and is enclosed by delimiters such as
<
and
>
.
Serial Cmd:
<
K201,serial trigger character
>
Default:
Spacebar
(corresponds to
<SP>
displayed in the embedded menu)
Options:
Any single ASCII character, including control characters, except
NUL
(
00H
),
an existing host command character, or an on-line protocol character. Control
characters entered on the command line are displayed in the menu as
mnemonic characters.
Usage:
It is useful in applications where different characters are required to start
and end a read cycle.
Definition:
A non-delimited trigger character is one that either starts or ends the read
cycle and is NOT enclosed by delimiters such as
<
and
>
.
Both Start and Stop non-delimited characters can be defined and will
function according to the trigger event, as follows:
When defining Start and Stop trigger characters, the following rules apply:
• In External Edge the reader looks only for the start trigger character and
ignores any end trigger character that may be defined.
• In External Level, the start trigger character begins the read cycle and end
trigger character ends it. Note that even after a symbol has been decoded
and the symbol data transmitted, the reader remains in External Level
trigger read cycle until a Stop character is received.
• In Serial Data & Edge trigger mode, command, either a start trigger
character or a hardware trigger can start an edge trigger read cycle.
Содержание Quadrus EZ
Страница 1: ...Quadrus EZ Reader User s Manual P N 83 006700 Rev T...
Страница 116: ...4 32 Quadrus EZ Reader User s Manual Background Color...
Страница 172: ...5 56 Quadrus EZ Reader User s Manual Output 3 Parameters...
Страница 186: ...6 14 Quadrus EZ Reader User s Manual Static Symbol Quality Outputs...
Страница 208: ...8 8 Quadrus EZ Reader User s Manual Service Message...
Страница 232: ...9 24 Quadrus EZ Reader User s Manual Other Camera Parameters...
Страница 252: ...11 6 Quadrus EZ Reader User s Manual Terminal Window Menus...
Страница 294: ...14 14 Quadrus EZ Reader User s Manual Ordered Output Filter...
Страница 346: ...A 42 Quadrus EZ Reader User s Manual Glossary of Terms...