Quadrus EZ Reader User’s Manual
5-43
I/O Parameters
Trend Analysis Mode
Mismatch
Output will be activated when the number of Mismatches equals the value entered for
Number to Output On within the trigger window selected in Number of Triggers.
Noread
Output will be activated when the number of noreads equals the value entered for Number
to Output On within the trigger window selected in Number of Triggers.
Bad Symbol
Output will be activated when the number of Bad Symbol occurrences equals the value
entered for Number to Output On within the trigger window selected in Number of
Triggers.
No Symbol
Output will be activated when the number of No Symbol occurrences equals the value
entered for Number to Output On within the trigger window selected in Number of
Triggers.
Definition:
Sets the trend condition (Mismatch, Noread, or Reads/Trigger) that will
activate the output.
Serial Cmd:
<
K780,trend analysis mode
,number of triggers,number to output on>
Default:
Noread
Options:
0 = Mismatch
1 = Noread
2 = Unused
3 = Bad Symbol
4 = No Symbol
Содержание Quadrus EZ
Страница 1: ...Quadrus EZ Reader User s Manual P N 83 006700 Rev T...
Страница 116: ...4 32 Quadrus EZ Reader User s Manual Background Color...
Страница 172: ...5 56 Quadrus EZ Reader User s Manual Output 3 Parameters...
Страница 186: ...6 14 Quadrus EZ Reader User s Manual Static Symbol Quality Outputs...
Страница 208: ...8 8 Quadrus EZ Reader User s Manual Service Message...
Страница 232: ...9 24 Quadrus EZ Reader User s Manual Other Camera Parameters...
Страница 252: ...11 6 Quadrus EZ Reader User s Manual Terminal Window Menus...
Страница 294: ...14 14 Quadrus EZ Reader User s Manual Ordered Output Filter...
Страница 346: ...A 42 Quadrus EZ Reader User s Manual Glossary of Terms...