Quadrus EZ Reader User’s Manual
5-51
I/O Parameters
Diagnostics
Note: When Diagnostic Warning is enabled under Output 1 Parameters, Output Mode
configuration has no effect.
Over Temperature
Service Unit
External Camera Disconnect
Note: This feature cannot be used if in a Continuous Read mode.
Usage:
Alerts user to critical conditions.
Definition:
Sets up specific warnings that will cause activation on output 1.
The output will remain active as long as one of the diagnostic conditions is
met. The output will go inactive as soon as it detects no active diagnostic
warning.
Definition:
Setups the output to toggle active when an over-temperature condition is
detected.
Serial Cmd:
<
K790,over temp
,service unit,external camera disconnect>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Definition:
Setups the output to toggle active when the service timer has expired. This
condition will only be held for one service timer tick.
Serial Cmd:
<
K790,
over temp,
service unit
,external camera disconnect>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Definition:
Setups the output to toggle active if the external camera goes off-line.
Serial Cmd:
<
K790,
over temp,service unit,
external camera disconnect
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Содержание Quadrus EZ
Страница 1: ...Quadrus EZ Reader User s Manual P N 83 006700 Rev T...
Страница 116: ...4 32 Quadrus EZ Reader User s Manual Background Color...
Страница 172: ...5 56 Quadrus EZ Reader User s Manual Output 3 Parameters...
Страница 186: ...6 14 Quadrus EZ Reader User s Manual Static Symbol Quality Outputs...
Страница 208: ...8 8 Quadrus EZ Reader User s Manual Service Message...
Страница 232: ...9 24 Quadrus EZ Reader User s Manual Other Camera Parameters...
Страница 252: ...11 6 Quadrus EZ Reader User s Manual Terminal Window Menus...
Страница 294: ...14 14 Quadrus EZ Reader User s Manual Ordered Output Filter...
Страница 346: ...A 42 Quadrus EZ Reader User s Manual Glossary of Terms...