5-6
Quadrus EZ Reader User’s Manual
When to Output Symbol Data
When to Output Symbol Data
As Soon As Possible
End of Read Cycle
Definition:
This command allows the user to choose when symbol data can be sent to
the host.
Serial Cmd:
<
K705,
symbol data output status,
when to output
>
Default:
As Soon As Possible
Options:
0 = As Soon As Possible
1 = End of Read Cycle
Usage:
As Soon As Possible is useful in applications in which symbol data needs
to be moved quickly to the host, typically when the host is making decisions
based on symbol data.
Definition:
Enabling
As Soon As Possible
causes symbol data to be sent to the host
immediately after a symbol has been successfully decoded.
Note: More than one decode might in fact be required to qualify as a good
read, depending on how Decodes Before Output is set.
Usage:
End of Read Cycle is useful in timing-based systems in which the host is
not ready to accept data at the time it is decoded.
Definition:
Enabling
End of Read Cycle
means that symbol data does not get sent to
the host until the read cycle ends with a timeout or new trigger.
Read Cycle
Read cycle duration
Start of read cycle
End of read cycle
This is when host
expects output
Host
activates trigger
Содержание Quadrus EZ
Страница 1: ...Quadrus EZ Reader User s Manual P N 83 006700 Rev T...
Страница 116: ...4 32 Quadrus EZ Reader User s Manual Background Color...
Страница 172: ...5 56 Quadrus EZ Reader User s Manual Output 3 Parameters...
Страница 186: ...6 14 Quadrus EZ Reader User s Manual Static Symbol Quality Outputs...
Страница 208: ...8 8 Quadrus EZ Reader User s Manual Service Message...
Страница 232: ...9 24 Quadrus EZ Reader User s Manual Other Camera Parameters...
Страница 252: ...11 6 Quadrus EZ Reader User s Manual Terminal Window Menus...
Страница 294: ...14 14 Quadrus EZ Reader User s Manual Ordered Output Filter...
Страница 346: ...A 42 Quadrus EZ Reader User s Manual Glossary of Terms...