2-26
Quadrus EZ Reader User’s Manual
Response Timeout
Response Timeout
Usage:
Only used when a response is required from the host. While in Multidrop, if
the reader does not receive an ACK or NAK from the host after sending
polled data, it will act on a fault. The reader can be set to wait indefinitely by
setting Response Timeout to zero.
Definition:
Time the reader will wait before timing out if ACK, NAK, and ETX are
enabled, and a host response is expected.
Serial Cmd:
<
K143,response timeout
>
Default:
2
(in 10mS increments =
20
mS)
Options:
0 to 255 (A zero (0) setting causes an indefinite wait.)