Code Type Commands
MS-850 Raster Scanner User’s Manual
3-13
3–Ser
ial
Conf
ig.
Code Type Commands
Note
: You can enable code types individually, or collectively with a <P> command.
Code 39
Format: <
Q
>
Allows only Code 39 labels to be read.
Format: <
Kp
status,check digit status,check digit output status,large intercharacter
gap,fixed code length status,code length,full ASCII Set
>
Example: To set Fixed Code Length to 30, send <K,,,,1,30> or <Kp1,0,0,0,1,30>.
I 2 of 5
Format: <
S
>
Allows only Interleaved 2 of 5 labels to be read.
Format: <
Kr
status,check digit status,check digit output status,code length #1,code
length #2
>
Example: To set Fixed Code Length #1 to 8 and Fixed Code Length #2 to 4, send
<Kr1,,,8,4> or <Kr1,0,0,8,4>.
status:
0 = Disabled
1 = Enabled
check digit status:
0 = Disabled
1 = Enabled
check digit output status:
0 = Disabled
1 = Enabled
full ASCII Set
0 = Disabled
1 = Enabled
large inter-
character gap
:
0 = Disabled
1 = Enabled
fixed code length
status:
0 = Disabled
1 = Enabled
code length:
Default is 10.
Any number from 1 to 64.
status:
0 = Disabled
1 = Enabled
check digit status:
0 = Disabled
1 = Enabled
check digit output status:
0 = Disabled
1 = Enabled
code length #1:
Default is
10
.
Zero or any even
number from 2 to 64.
code length #2:
Default is
6
.
Zero or any even
number from 2 to 64.