Operations Commands
MS-850 Raster Scanner User’s Manual
3-11
3–Ser
ial
Conf
ig.
Good Decode Reads
Format: <
Km
number of reads
>
Example: To change Good Decode Reads to 3, send <Km3>.
Match Code
Format: <
Kn
type,sequential matching,match start position,match length,wild card
character,sequence on noread,sequence on every mismatch
>
Example: To enable Match Code Type for Sequential, set Sequential Matching for Decre-
ment, and enable Sequence on Every Mismatch, send <Kn3,1,,,,,1>.
Master Label Database Size
Format: <
KM
number of master labels
>
Example: To change the number of master labels to 4, send <KM4>.
number of reads (before a good decode):
Default is
1
.
Any number from 1 to 31.
type:
0 = Disabled
1 = Enabled
2 = Sequential
3 = Wild Card
sequential matching:
0 = Increment
1 = Decrement
match start position:
Default is
0
0 to 64
match length
Default is
1
.
1 to 64
wild card character
Default is
*
.
Any ASCII character.
sequence on noread:
0 = disabled
1 = enabled
When disabled, the scanner does not sequence (increment
or decrement) on a noread. When enabled, the scanner
sequences on every noread.
If 001, 002 noread, then
search for 003.
If 001, 002 noread, then
search for 004.
sequence on every mismatch:
0 = disabled
1
=
enabled
When disabled, if a mismatch is out of sequence by no more
than 1, then the sequence resumes and searches indefi-
nitely. When enabled, the scanner sequences on every mis-
match.
If 001, 002,
004 (mismatch), then
search for 005.
If 001, 002, mismatch,
then search for 004. If
mismatch occurs again,
then search for 005, etc.
status:
Default is
1
.
Any number from 1 to 10