Chapter 2
Menu Configuration
2-36
MS-850 Raster Scanner User’s Manual
2–Menu Conf
ig
.
downloaded into memory.
Note
: To activate on a Good Read, set Output On to Match and disable Match Code Type.
Match (or Good Read)
Activates output pins when the decoded label matches the master label. To send the
pulse on a good read, disable Match Code Type.
Mismatch
Activates output pins when the label’s data does not match that of the master label.
Mismatch or Noread
Activates output pins when the label's data does not match that of the master label or
the label is not decoded before the end of the read cycle.
Noread
Activates output pins when the label’s data is not decoded before the end of the read
cycle.
Preamble (enable/disable)
Default:
Disabled
Options:
Disabled, Enabled (within any protocol)
Allows you to enable or disable the preamble character(s).
Preamble
Default:
^M
(and a null). Corresponds to <CR><NUL><NUL><NUL> (carriage
return/null/null/null) displayed in the menu.
Options: Up to four user defined ASCII characters, including control characters. Con-
trol characters entered on the command line are displayed in the menu as
mnemonic characters.
Allows you to define a one to four character data string that can be added to the front
of the decoded data.
Postamble (enable/disable)
Default:
Enabled
Options:
Enabled, Disabled (within any protocol)
Allows you to enable or disable the Postamble character(s).