manualshive.com logo in svg
background image

™ 

IMAGETEAM™ 2020/5620

Cordless System

System Manual

Содержание IMAGETEAM 5620

Страница 1: ...IMAGETEAM 2020 5620 Cordless System System Manual...

Страница 2: ...ein nor for incidental or consequential damages resulting from the furnishing performance or use of this material This document contains proprietary information which is protected by copyright All rig...

Страница 3: ...vice pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can ra...

Страница 4: ...RF exposure guidelines for body worn operation do not use accessories that contain metallic components and ensure that the device is at least 15mm 0 6 inches from the body Canadian Compliance This Cla...

Страница 5: ...Federal Communications Commission FCC Bluetooth Radio Device R TTE Compliance Statement These devices are in conformity with all essential requirements of the R TTE Directive 1999 5 EC This equipment...

Страница 6: ...ement T V or GS marked to EN60950 and EN60825 1 C Tick Statement Conforms to AS NZS 3548 C Tick number N10410 Mexico Patents Please refer to the IT5620 packaging for patent information Solids and Wate...

Страница 7: ...Required Safety Labels IT5620...

Страница 8: ...g g 0 0 D G D Q D F Q V W F X G R U 3 G O H G Q D 1 V O O D V H O H W D H Q D N 6 D Q L K Q L H G D 0 J Q L G Q H 3 V W Q H W D 3 Q J L H U R G Q D 6 8 7 5 2 6 6 M O C D L E H D N A H W W W IT2020...

Страница 9: ...Changing Scanner Name Serially 1 8 Changing Scanner Name via Bar Codes 1 9 Scanner Report 1 10 Application Work Groups 1 10 Application Work Group Selection 1 11 Resetting the Standard Product Default...

Страница 10: ...ation Plug Play 1 22 IBM 4683 Ports 5B 9B and 17 Interface 1 23 Connecting the Base with USB 1 24 IBM SurePos 1 25 USB PC or Macintosh Keyboard 1 25 USB HID 1 26 USB Com Port Emulation 1 26 Connecting...

Страница 11: ...eeper Volume Good Read 3 1 Beeper Pitch Good Read 3 2 Beeper Duration Good Read 3 2 LED Good Read 3 2 Number of Beeps Good Read 3 3 Good Read Delay 3 3 User Specified Good Read Delay 3 3 Scanner Trigg...

Страница 12: ...r Delay 4 5 User Specified Intercharacter Delay 4 5 Interfunction Delay 4 6 Intermessage Delay 4 6 Chapter 5 Data Formatting Data Format Editor Introduction 5 1 To Add a Data Format 5 1 Other Programm...

Страница 13: ...2 of 5 Message Length 6 12 IATA Code 2 of 5 Message Length 6 13 Matrix 2 of 5 6 13 Matrix 2 of 5 Message Length 6 14 Code 11 6 14 Check Digits Required 6 14 Code 11 Message Length 6 15 Code 128 6 15 I...

Страница 14: ...slate 6 25 EAN JAN 8 6 25 EAN JAN 8 Check Digit 6 25 EAN JAN 8 Addenda 6 26 EAN JAN 8 Addenda Required 6 26 EAN JAN 8 Addenda Separator 6 26 MSI 6 27 MSI Check Character 6 27 MSI Message Length 6 28 P...

Страница 15: ...Settings Current Application Work Group 8 2 Resetting the Standard Product Default Settings All Application Work Groups 8 3 Temporary Visual Menu 2003 Configuration 8 3 Chapter 9 Visual Menu 2003 Visu...

Страница 16: ...intenance Maintenance 12 1 Cleaning the Scanner s Window 12 1 Inspecting Cords and Connectors 12 1 Replacing the IT2020 Interface Cable 12 2 Troubleshooting Base 12 2 Chapter 13 Customer Support Produ...

Страница 17: ...ility an advanced two way spread spectrum radio Bluetooth wireless technology a wide range of interfaces keyboard wedge wand emulation RS 232 terminals USB and legacy decoders visible and audible feed...

Страница 18: ...red is present Save the shipping container for later storage or shipping Check for damage during shipment Report damage immediately to the carrier who delivered the carton Models Models Description 20...

Страница 19: ...less scanner by a rechargeable battery that is integrated in the scanner handle Each scanner is shipped with a battery See Product Specifications beginning on page 11 1 Charging Information The batter...

Страница 20: ...es it will eventually be depleted Replace it after the battery is unable to hold an adequate charge If you are not sure if the battery or charger is working properly send it to Hand Held Products or a...

Страница 21: ...power source only The chart below describes each selection by condition Using a slow charge rate draws less current power from the input power source when the battery is mostly discharged Scan the ap...

Страница 22: ...cordless system is set up correctly scan one of the sample bar codes in the back of this manual If the scanner provides a single good read beep and the green LED lights the scanner has successfully li...

Страница 23: ...ner by scanning the Unlink Scanner bar code See Scanner Modes on page 1 6 Open Link Mode Single Scanner When newly shipped or defaulted to factory settings the base and scanner are not linked By placi...

Страница 24: ...nners linked to one base so that you will be able to control the scanner receiving imaging commands sent from the base The default name for an IT5620 is IT5620 If you have more than one IT5620 linked...

Страница 25: ...code below with the first scanner scan the 1 bar code on the Programming Chart inside the back cover of this manual and scan Save Then scan the Reset bar code and wait for the scanner to re link to th...

Страница 26: ...k group and may program each scanner independently Visual Menu 2003 page 9 1 makes it easy for you to program your system for use with multiple scanners and multiple work groups The scanner keeps a co...

Страница 27: ...his programming selection allows you to assign an scanner to a work group by scanning the bar code below You may then program the settings e g beeper volume prefix suffix data formatter that your appl...

Страница 28: ...to Base on page 1 6 for additional information Note If your scanner is in multiple scanner mode and you scan either the current or all application group default bar code you will hear up to 30 seconds...

Страница 29: ...de Some devices require a PIN code as part of the Bluetooth security features Your scanner s default PIN is 1234 which you may need to enter the first time you connect to your PDA or PC The PIN code m...

Страница 30: ...fit your application Data Accumulation Mode Scan the bar codes below to turn data accumulation batch mode on and off If data accumulation mode is on bar code data is stored when the scanner is out of...

Страница 31: ...l Operation Red Flash None Battery low Green Flash 1 beep Successful communication or linking Red blinking 3 beeps Failed communication Menu Operation Green Flash 2 beeps Successful menu change Red bl...

Страница 32: ...s according to the Charge Status Indicator table above The base can be powered by the Host parasitic power mode If the base is in parasitic power mode without the 9VDC power source the base will still...

Страница 33: ...software automatically detects the imager and links it to the base depending on the selected link mode Scanner Is Out of Range The cordless scanner is in communication with its base even when it is n...

Страница 34: ...r the base indicates that the data sent was received by the host The cordless scanner recognizes data acknowledgement ACK from the base unit If it cannot be determined that the data has been properly...

Страница 35: ...board wedge interface See Keyboard Wedge Connection on page 1 21 6 Verify the base operation by scanning a bar code from the Sample Symbols in the back of this manual Note Without using the 9 volt ext...

Страница 36: ...aiming line on the symbol Resetting the Standard Product Defaults If you aren t sure what programming options are in your scanner or you ve changed some options and want the factory settings restored...

Страница 37: ...allows operation of the scanner in parallel with the integral keyboard The following Laptop Direct Connect bar code selects terminal ID 03 programs a carriage return CR suffix and turns on Emulate Ext...

Страница 38: ...onverts all other symbologies to Code 39 The Wand Emulation Plug Play Code 39 Format bar code below sets the terminal ID to 61 The Wand Emulation Plug Play Same Code Format bar code sets the terminal...

Страница 39: ...the following suffixes for each symbology Suffixes programmed for Code 128 with IBM 4683 Port 5B IBM 4683 Port 9B HHBCR 1 and IBM 4683 Port 17 Interfaces Suffixes programmed for Code 128 with IBM 468...

Страница 40: ...ion by scanning a bar code from the Sample Symbols in the back of this manual For additional USB programming and technical information refer to Hand Held Products USB Application Note available at www...

Страница 41: ...g suffixes for each symbology USB PC or Macintosh Keyboard Scan one of the following codes to program the IT5620 for USB PC Keyboard or USB Macintosh Keyboard Scanning these codes adds a CR and LF alo...

Страница 42: ...PC you will need to download a driver from the Hand Held Products website www handheld com The driver will use the next available Com Port number Apple Macintosh computers recognize the scanner as a...

Страница 43: ...xisting serial cable from the computer 3 Connect the appropriate interface cable to the base Note For the base to work properly you must have the correct cable for your type of computer 4 Plug the ser...

Страница 44: ...l wedge terminal ID use the serial terminal ID 050 and follow the instructions on page 2 1 Make sure that all of the communication parameters match on all of the connected devices Choosing Both sends...

Страница 45: ...our terminal ID Scan Save to save your selection For example an IBM AT terminal has a Terminal ID of 003 You would scan the Terminal ID bar code then 0 0 3 from the Programming Chart inside the back c...

Страница 46: ...3488 008 IBM 122 key 3180 024 IBM 122 key 3180 data entry keyboard 114 IBM DOS V 106 key PC Workstation 102 IBM SurePOS USB Hand Held Scanner 128 IBM SurePOS USB Tabletop Scanner 129 IBM Thinkpad 360...

Страница 47: ...erfaces rather than scanning the terminal ID listed in this table Telex 122 key 078 078A 79 80 191 196 1191 1192 1471 1472 1476 1477 1482 1483 046 USB PC Keyboard 124 USB Mac Keyboard 125 USB Com Port...

Страница 48: ...y code below to program the keyboard for your country As a general rule the following characters are supported but need special care for countries other than the United States United States Denmark Fr...

Страница 49: ...Caps Lock is used when you normally have the Caps Lock key on Shift Lock is used when you normally have the Shift Lock key on not common to U S keyboards Automatic Caps Lock is used if you change the...

Страница 50: ...SCII Mode On The scanner sends key combinations for ASCII control characters for values 00 1F Refer to Keyboard Function Relationships page 7 1 for CTRL ASCII Values Default Off Turbo Mode The scanner...

Страница 51: ...e interface cable to the base Note For the base to work properly you must have the correct cable for your type of terminal computer 3 Plug the serial connector into the serial port on your computer Ti...

Страница 52: ...32 interface bar code programs the scanner for an RS 232 interface at 115 200 baud parity none 8 data bits 1 stop bit and adds a suffix of a CR LF RS 232 Baud Rate Baud Rate sends the data from the sc...

Страница 53: ...bits For applications which require use of the full ASCII set select 8 data bits per character Default 8 Stop Bits sets the stop bits at 1 or 2 Default 1 Parity provides a means of checking character...

Страница 54: ...indicators emitted from the source scanner Turning the Host ACK selection on configures the cordless system scanners to respond to commands from the host system The following criteria must be met for...

Страница 55: ...The scanner reads a code and sends data to the base host system No audible or visual indication is emitted until you receive an escape command The scanner read illumination goes out upon a successful...

Страница 56: ...lluminate green LED for two seconds followed by at least 500 mSecs dark time when multiple blinks ESC 3 Illuminate green LED for five seconds followed by at least 500 mSecs dark time when multiple bli...

Страница 57: ...o changing the terminal ID Please refer to Wand Emulation Plug Play on page 1 22 for further information In Wand Emulation mode the imager decodes the bar code then sends data in the same format as a...

Страница 58: ...ate is limited by the terminal s ability to receive data without dropping characters Default 25 inches second Wand Emulation Polarity The Polarity can be sent as standard with black bars high or rever...

Страница 59: ...et the scanner s idle state to match the idle state for the device to which the scanner is connected Default Idle High Wand Emulation Data Block Size This transmits the data in smaller blocks to preve...

Страница 60: ...ed on a computed check character is added at the end of the entire message The check character is the character which when Exclusive OR d with every preceding character of the message yields a result...

Страница 61: ...sponse to a good read Turning this option off only turns off the beeper response to a good read indication All error and menu beeps are still audible Default On Beeper Volume Good Read The beeper volu...

Страница 62: ...od read Default Medium Beeper Duration Good Read The beeper duration codes modify the length of the beep the scanner emits on a good read Default Normal LED Good Read The LED indicator can be programm...

Страница 63: ...ps scan the bar code below and then scan a digit 1 9 bar code and the Save bar code on the Programming Chart inside the back cover of this manual Default One Good Read Delay This sets the minimum amou...

Страница 64: ...l Trigger Mode Use this selection to set a time out in milliseconds of the scanner s trigger when using serial commands to trigger the scanner Once the scanner has timed out you can activate the scann...

Страница 65: ...down mode pull the trigger to power the unit back up There will be a set of power up beeps and a delay of up to a few seconds for the radio to join The scanner will then be ready to use Automatic Tri...

Страница 66: ...e back cover and Save Default 5 000 ms Reread Delay This sets the time period before the scanner can read the same bar code a second time Setting a reread delay protects against accidental rereads of...

Страница 67: ...e must be within the window to be decoded or output by the scanner To change the left or right edge of the centering window scan Centering On then scan one of the following bar codes Then scan the per...

Страница 68: ...hatever order your application requires regardless of the order in which the bar codes are scanned Reading the Default Sequence symbol programs the scanner to the Universal values shown below These ar...

Страница 69: ...his manual to read the alphanumeric combination that represents the ASCII characters 99 is the Universal num ber indicating all characters 5 End Output Sequence Editor Scan F F to enter an Output Sequ...

Страница 70: ...ut Code 39 1st Code 128 2nd and Code 93 3rd as shown below Note Code 93 must be enabled to use this example You would set up the sequence editor with the following command line SEQBLK62999941FF6A99994...

Страница 71: ...formatted characters as part of the length If you use the example on page 3 10 but assume a CR suffix and specific code lengths you would use the following command line SEQBLK62001241FF6A001342FF69001...

Страница 72: ...the scanner sends an NR to the host if you pull and release the trigger without reading a code e g bad bar code If No Read is turned Off the NR will not be sent to the host If you want a different no...

Страница 73: ...oints to Keep In Mind It is not necessary to build a message string The selections in this chapter are only used if you wish to alter the default settings Default prefix None Default suffix None A pre...

Страница 74: ...ffix character Step 7 To add the Code I D scan 5 C 8 0 To add AIM I D scan 5 C 8 1 To add a backslash scan 5 C 5 C Note To add a backslash as in Step 7 you must scan 5C twice once to create the leadin...

Страница 75: ...igit Hex value from the Symbology Chart included in the Appendix A for the symbology from which you want to clear the pre fix or suffix Step 3 Scan the 2 digit hex value from the Programming Chart ins...

Страница 76: ...nner is in keyboard wedge mode the scan code is converted to a key code before it is transmitted Default Enable Intercharacter Interfunction and Intermessage Delays Some terminals drop information cha...

Страница 77: ...on User Specified Intercharacter Delay An intercharacter delay of up to 495 milliseconds may be placed after the transmission of a particular character of scanned data Scan the Delay Length bar code b...

Страница 78: ...ramming Chart inside the back cover of this manual Intermessage Delay An intermessage delay of up to 495 milliseconds may be placed between each scan transmission Scan the Intermessage Delay bar code...

Страница 79: ...tual Length 6 Universal Term ID Actual Code ID Universal Length 7 Universal Term ID Universal Code ID Actual Length 8 Universal Term ID Universal Code ID Universal Length If you have changed data form...

Страница 80: ...you are clearing an alternate format scan 1 2 or 3 depending on the alternate format you are clearing Scan the Terminal Type refer to the Supported Terminals Chart on page 2 2 Code I D refer to the Sy...

Страница 81: ...er Syntax F8xx xx stands for the hex value for an ASCII code see ASCII Conversion Chart Code Page 1252 on page A 2 F9 Search back for xx character from current cursor position leaving cursor pointing...

Страница 82: ...E Compare character in current cursor position to the character xx If char acters are equal increment cursor If characters are not equal no format match Syntax FExx xx stands for the hex value for an...

Страница 83: ...e shot capability to scan one bar code using a different data format than your primary format When data formats are programmed see page 5 1 you must input whether you are programming the primary forma...

Страница 84: ...5 6 IMAGETEAM 2020 5620 System Manual...

Страница 85: ...ies On code If on the other hand you want to decode only a particular symbology scan All Symbologies Off followed by the On symbol for that particular symbology All Symbologies IATA Code 2 of 5 China...

Страница 86: ...ps reduce the chances of a misread EXAMPLE Decode only those bar codes with a count of 9 20 characters Min length 09 Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min...

Страница 87: ...heck characters are created using different modulos You can program the scanner to read only Codabar bar codes with Modulo 16 check characters Default No Check Character No Check Character indicates t...

Страница 88: ...r looks for a Codabar symbol having a D start character adjacent to a symbol having a D stop character In this case the two messages are concatenated into one with the D characters omitted Default On...

Страница 89: ...imum and Maximum lengths 2 60 Minimum Default 4 Maximum Default 60 Code 39 Default All Code 39 Settings Code 39 Code 39 Start Stop Characters Start Stop characters identify the leading and trailing en...

Страница 90: ...with the scanned data When Check Character is set to Validate and Transmit the scanner only reads Code 39 bar codes printed with a check character and will transmit this character at the end of the s...

Страница 91: ...with a space excluding the start and stop symbols and does not immediately transmit the data The scanner stores the data in the order in which the bar codes are read deleting the first space from each...

Страница 92: ...gn and period respectively Character pairs P through Y decode as 0 through 9 NUL U DLE P SP SPACE 0 0 V P P W p P SOH A DC1 Q A 1 1 A A Q Q a A q Q STX B DC2 R B 2 2 B B R R b B r R ETX C DC3 S C 3 3...

Страница 93: ...the case scan the bar code below select the code page with which the bar codes were created from the chart Code Page Mapping of Printed Bar Codes on page A 4 and scan the value and the SAVE bar code f...

Страница 94: ...nner only reads Interleaved 2 of 5 bar codes printed with a check digit and will transmit this digit at the end of the scanned data Default No Check Digit Interleaved 2 of 5 Message Length Scan the ba...

Страница 95: ...ta received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this...

Страница 96: ...essage Length Scan the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48...

Страница 97: ...he bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 Matrix 2 of 5 Defau...

Страница 98: ...for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 Code 11 Default All Code 11 Settings Code 11 Check Digits Required This option sets whether 1 or 2 che...

Страница 99: ...the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 Code 128 Default...

Страница 100: ...lt Off Code 128 Message Length Scan the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 0 80 Minimum Default 0 M...

Страница 101: ...Default All Telepen Settings Telepen Telepen Output Using AIM Telepen Output the scanner reads symbols with start stop pattern 1 and decodes them as standard full ASCII start stop pattern 1 When Orig...

Страница 102: ...2 for additional information Minimum and Maximum lengths 1 60 Minimum Default 1 Maximum Default 60 UPC A Default All UPC A Settings UPC A UPC A Check Digit This selection allows you to specify whethe...

Страница 103: ...ot transmit it Default On UPC A Addenda This selection adds 2 or 5 digits to the end of all scanned UPC A data Default Off for both 2 Digit and 5 Digit Addenda UPC A Addenda Required When Addenda Requ...

Страница 104: ...pace between the data from the bar code and the data from the addenda When turned off there is no space Default On UPC A EAN 13 with Extended Coupon Code Use the following codes to enable or disable U...

Страница 105: ...number system use the UPC E1 selection Default On UPC E0 and Off UPC E1 UPC E0 and UPC E1 Expand UPC E Expand expands the UPC E code to the 12 digit UPC A format Default Off UPC E0 and UPC E1 Addenda...

Страница 106: ...rned off there is no space Default On UPC E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not Default On UPC E0 Number System The n...

Страница 107: ...for both 2 Digit and 5 Digit Addenda EAN JAN 13 Default All EAN JAN Settings EAN JAN 13 EAN JAN 13 Check Digit This selection allows you to specify whether the check digit should be transmitted at th...

Страница 108: ...When Addenda Required is set to on the scanner will only read EAN JAN 13 bar codes that have addenda Default Not Required EAN JAN 13 Addenda Separator When this feature is on there is a space between...

Страница 109: ...e 6 20 ISBN Translate This selection causes EAN 13 Bookland symbols to be translated into their equivalent ISBN number format Default Off EAN JAN 8 Default All EAN JAN 8 Settings EAN JAN 8 EAN JAN 8 C...

Страница 110: ...When Addenda Required is set to on the scanner will only read EAN JAN 8 bar codes that have addenda Default Not Required EAN JAN 8 Addenda Separator When this feature is on there is a space between t...

Страница 111: ...Check Character is set to Validate and Transmit the scanner will only read MSI bar codes printed with the specified type check character and will transmit this character at the end of the scanned dat...

Страница 112: ...Minimum Default 4 Maximum Default 48 Plessey Code Default All Plessey Code Settings Plessey Code Plessey Message Length Scan the bar codes below to change the message length Refer to Message Length o...

Страница 113: ...IMAGETEAM 2020 5620 System Manual 6 29 RSS 14 Default All RSS 14 Settings RSS 14 RSS Limited Default All RSS Limited Settings RSS Limited On Off On Off...

Страница 114: ...ximum lengths 4 74 Minimum Default 4 Maximum Default 74 EAN UCC Emulation The imager can automatically format the output from any EAN UCC data carrier to emulate what would be encoded in an equivalent...

Страница 115: ...nize one data carrier type Default EAN UCC Emulation Off China Post Code Default All China Post Code Settings China Post Code China Post Message Length Scan the bar codes below to change the message l...

Страница 116: ...e Korea Post Message Length Scan the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maxi...

Страница 117: ...e Length Scan the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 48 On O...

Страница 118: ...odes Trioptic Code must be off Codablock F Default All Codablock F Settings Codablock F Codablock F Message Length Scan the bar codes below to change the message length Refer to Message Length on page...

Страница 119: ...Message Length Scan the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 0 160 Minimum Default 1 Maximum Default...

Страница 120: ...Message Length Scan the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 1 81 Minimum Default 1 Maximum Default 8...

Страница 121: ...ls that can be used with the scanner Refer to page 2 6 enable Control ASCII mode Function Code HEX ASCII Value Full ASCII CTRL NUL 00 2 SOH 01 A STX 02 B ETX 03 C EOT 04 D ENQ 05 E ACK 06 F BEL 07 G B...

Страница 122: ...CTRL column 6 apply to US only The following chart indicates the equivalents of these five characters for different countries Country Codes United States 6 Belgium 6 Scandinavia 8 9 6 France 8 6 Germ...

Страница 123: ...CR Enter New Line BS 08 Reserved Reserved F16 HT 09 Tab Tab F17 LF 0A Reserved Reserved F18 VT 0B Tab Tab Tab Field Forward FF 0C Delete Delete Delete CR 0D CR Enter CR Enter Field Exit New Line SO 0...

Страница 124: ...LF 0A F18 Reserved VT 0B Tab Field Forward Field Forward FF 0C Delete Delete CR 0D Field Exit New Line SO 0E Insert Insert SI 0F Clear Erase DLE 10 Error Reset Error Reset DC1 11 Home Reserved DC2 12...

Страница 125: ...N A N A BEL 07 New Line New Line New Line BS 08 N A N A N A HT 09 Tab Tab Tab LF 0A N A N A N A VT 0B Tab Tab Tab FF 0C N A N A Delete CR 0D New Line New Line New Line SO 0E N A N A Insert SI 0F Escap...

Страница 126: ...e EOT 04 ALT break ENQ 05 CNTRL make ACK 06 CNTRL break BEL 07 RETURN BS 08 APPLE make HT 09 TAB LF 0A APPLE break VT 0B TAB FF 0C Del CR 0D RETURN SO 0E Ins Help SI 0F ESC DLE 10 F11 DC1 11 Home DC2...

Страница 127: ...removed when the unit is reset For instructions on how to reset your scanner refer to Reset Scanner page 8 1 Reset Scanner Scanning the following bar code clears temporary settings in the scanner and...

Страница 128: ...the bar code below to determine the address of the base you are using Resetting the Standard Product Default Settings Current Application Work Group If you aren t sure what programming options are in...

Страница 129: ...igure the scanner for Visual Menu 2003 settings Refer to Visual Menu 2003 on page 9 1for additional information about Visual Menu 2003 After using Visual Menu scan the Reset Scanner bar code on page 8...

Страница 130: ...8 4 IMAGETEAM 2020 5620 System Manual...

Страница 131: ...port and an RS 232 cable to connect the port to the device A power supply which plugs into the IT2020 5A is also required Note IT5620 IT2020 5A works only with Visual Menu 2003 version 4 2 or later Vi...

Страница 132: ...stem Manual 6 Double click on the Visual Menu 2003 exe file Follow the screen prompts to install the Visual Menu 2003 program 7 To start Visual Menu 2003 from the Start Menu click on Programs Visual M...

Страница 133: ...ndows that appear on the screen Menu Command Syntax Menu commands have the following syntax spaces have been used for clarity only Prefix Name Tag SubTag Data SubTag Data Tag SubTag Data Storage Prefi...

Страница 134: ...es for the setting s The de vice s response uses a dash to indicate a continuous range of values A pipe separates items in a list of non continuous val ues Name Field Usage Optional This command retur...

Страница 135: ...bTag combination e g an entry for a minimum message length of 100 when the field will only accept 2 characters When responding the device echoes back the command sequence with the status character ins...

Страница 136: ...o 60 characters and the Default setting DFT has no value Trigger Commands You can activate and deactivate the scanner with serial trigger commands First the scanner must be put in Manual Serial Trigge...

Страница 137: ...to Base on page 1 6 for additional information Note If your scanner is in multiple scanner mode and you scan either the current or all application group default bar code you will hear up to 30 seconds...

Страница 138: ...Imager Name Imager Name BT_NAM 1 9 Imager Report Imager Report RPT_SCN 1 10 Application Work Group Selections Group 0 GRPSEL0 1 11 Group 1 GRPSEL1 1 11 Group 2 GRPSEL2 1 11 Group 3 GRPSEL3 1 11 Group...

Страница 139: ...n KBDCTY7 2 4 Italy KBDCTY5 2 4 Norway KBDCTY9 2 4 Spain KBDCTY10 2 4 Switzerland KBDCTY6 2 4 Keyboard Style Regular KBDSTY0 2 5 Caps Lock KBDSTY1 2 5 Shift Lock KBDSTY2 2 5 Automatic Caps Lock KBDSTY...

Страница 140: ...Stop Parity Odd 232WRD6 2 9 7 Data 2 Stop Parity Even 232WRD4 2 9 7 Data 2 Stop Parity None 232WRD1 2 9 7 Data 2 Stop Parity Odd 232WRD7 2 9 8 Data 1 Stop Parity Even 232WRD5 2 9 8 Data 1 Stop Parity...

Страница 141: ...2 15 60 WNDBLK2 2 15 80 WNDBLK3 2 15 Wand Emulation Delay Between Blocks 5ms WNDDLY0 2 15 50ms WNDDLY1 2 15 150ms WNDDLY2 2 15 500ms WNDDLY3 2 15 Wand Emulation Overall Checksum Off WNDCHK0 2 16 On W...

Страница 142: ...YGRD 3 3 Trigger Mode Manual Trigger TRGMOD0 3 4 Read Time Out 0 300 000 ms 300 000 TRGSTO 3 4 Scanner Power Time Out Timer 0 7200 seconds 3600 BT_LPT0 3 5 BT_LPT200 3 5 BT_LPT400 3 5 BT_LPT900 3 5 BT...

Страница 143: ...0 3 12 Video Reverse On VIDREV1 3 12 Off VIDREV0 3 12 Prefix Suffix Selections Add CR Suffix to All Symbologies VSUFCR 4 3 Prefix Add Prefix PREBK2 4 3 Clear One Prefix PRECL2 4 3 Clear All Prefixes P...

Страница 144: ...All Symbologies On ALLENA1 6 1 Codabar Default All Codabar Settings CBRDFT 6 3 Codabar Off CBRENA0 6 3 On CBRENA1 6 3 Codabar Start Stop Char Don t Transmit CBRSSX0 6 3 Transmit CBRSSX1 6 3 Codabar Ch...

Страница 145: ...5 Default All Interleaved 2 of 5 Settings I25DFT 6 9 Interleaved 2 of 5 Off I25ENA0 6 9 On I25ENA1 6 9 Interleaved 2 of 5 Check Digit No Check Char I25CK20 6 10 Validate But Don t Transmit I25CK21 6...

Страница 146: ...m 1 80 80 X25MAX 6 14 Code 11 Default All Code 11 Settings C11DFT 6 14 Code 11 Off C11ENA0 6 14 On C11ENA1 6 14 Code 11 Check Digits Required 1 Check Digit C11CK20 6 14 2 Check Digits C11CK21 6 14 Cod...

Страница 147: ...On UPAENA1 6 18 UPC A Check Digit Off UPACKX0 6 18 On UPACKX1 6 18 UPC A Number System Off UPANSX0 6 19 On UPANSX1 6 19 UPC A 2 Digit Addenda Off UPAAD20 6 19 On UPAAD21 6 19 UPC A 5 Digit Addenda Of...

Страница 148: ...AN JAN 13 Off E13ENA0 6 23 On E13ENA1 6 23 EAN JAN 13 Check Digit Off E13CKX0 6 23 On E13CKX1 6 23 EAN JAN 13 2 Digit Addenda Off E13AD20 6 24 On E13AD21 6 24 EAN JAN 13 5 Digit Addenda Off E13AD50 6...

Страница 149: ...Don t Transmit MSICHK0 6 27 Validate Type 10 and Transmit MSICHK1 6 27 MSI Message Length Minimum 4 48 4 MSIMIN 6 28 Maximum 4 48 48 MSIMAX 6 28 Plessey Code Default All Plessey Settings PLSDFT 6 28 P...

Страница 150: ...e Default All Korea Post Code Settings KPCDFT 6 32 Korea Post Code Off KPCENA0 6 32 On KPCENA1 6 32 Korea Post Code Msg Length Minimum 2 80 4 KPCMIN 6 32 Maximum 2 80 48 KPCMAX 6 32 PosiCode Default A...

Страница 151: ...ngs 16KDFT 6 35 Code 16K Off 16KENA0 6 35 On 16KENA1 6 35 Code 16K Minimum 0 160 1 16KMIN 6 35 Maximum 0 160 160 16KMAX 6 35 Code 49 Default All Code 49 Settings C49DFT 6 35 Code 49 Off C49ENA0 6 36 O...

Страница 152: ...10 20 IMAGETEAM 2020 5620 System Manual...

Страница 153: ...65 degrees Horizontal Velocity 2 inches 5 cm per second Scan Contrast 20 minimum Battery Lithium Ion 3 6 Volt 1600 mAHr minimum Battery Capacity Standby Heavy Usage 1 scan per second 20 hours 12 hours...

Страница 154: ...0mA will not charge 9 Volt DC Barrel 100 750mA 12 volt Host 100 150mA Charge Rate 41 F to 104 F 5 C to 40 C 9 Volt DC Barrel external power Maximum 4 hours full charge for fully discharged battery Tem...

Страница 155: ...nimum Far Field no ambient lighting 13 mil 100 UPC 1 in 2 5 cm 24 in 61 cm 7 5 mil Code 39 4 in 10 cm 14 in 36 cm 10 mil Code 39 2 in 5 cm 18 in 46 cm 13 mil Code 39 1 in 2 5 cm 24 in 61 cm 15 mil Cod...

Страница 156: ...Cable Pinouts Keyboard Wedge 10 Pin RJ41 Modular Plug connects to the base 1 2 Cord shield 3 Tied to supply power 4 Supply ground 5 Terminal clock 6 Terminal data 7 Supply power input Refer to tables...

Страница 157: ...to the base 1 2 Cord shield 3 Prog 1 Tied to supply power for primary cable 4 Supply ground 5 6 Bar code data output 7 Supply power input Refer to tables on page 11 2 8 9 10 Bar code data output Supp...

Страница 158: ...odular Plug connects to the base 1 2 Cord shield 3 Prog 1 Tied to supply power for primary cable 4 Supply ground 5 Receive data Serial data to scanner 6 Transmit data Serial data from scanner 7 Supply...

Страница 159: ...IMAGETEAM 2020 5620 System Manual 11 7 Standard Cable Pinouts USB 10 Pin Modular Plug connects to the base 1 2 Data 3 Tied to supply power 4 Supply ground 5 6 7 5 volt supply power input 8 9 10 Data...

Страница 160: ...11 8 IMAGETEAM 2020 5620 System Manual...

Страница 161: ...nt solution is used rinse with a clean lens tissue dampened with water only The base and scanner s housing may also be cleaned the same way Inspecting Cords and Connectors Inspect the base s interface...

Страница 162: ...the IT5620 Battery 1 Remove the screw on the end cap 2 Remove the battery from the handle 3 Insert battery 4 Replace end cap and screw Troubleshooting Base Note Please visit the Services and Support...

Страница 163: ...to which the scanner connects Is the bar code displayed but not entered into the application The bar code is displayed on the host device correctly but you still have to press a key to enter it the En...

Страница 164: ...canner still can t read the sample bar codes scan All Symbologies on page 6 1 If you aren t sure what programming options have been set in the base or if you want the factory default settings restored...

Страница 165: ...cts Corporate Offices Telephone 800 782 4263 Option 3 Fax 704 566 6015 E mail naservice handheld com America Latina Hand Held Products America Latina Tel fono 239 263 7600 Fax 239 263 9689 E mail lase...

Страница 166: ...Online Technical Assistance You can also access technical assistance online at www handheld com Limited Warranty Hand Held Products Inc Hand Held Products warrants its products to be free from defect...

Страница 167: ...TO THE REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT IN NO EVENT SHALL HAND HELD PRODUCTS BE LIABLE FOR INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES AND IN NO EVENT SHALL ANY LIABILITY OF HAND HELD P...

Страница 168: ...13 4 IMAGETEAM 2020 5620 System Manual...

Страница 169: ...x ID China Post Q X0 51 Korea Post X0 3F Codabar a Fm 61 Matrix 2 of 5 m X0 6D Codablock F q Om 71 MSI g Mm 67 Code 11 h Hm 68 No Read 9C Code 16K o Km 6F Plessey Code n P0 6E Code 39 b Am 62 PosiCode...

Страница 170: ...T 169 29 233 49 l 297 69 i 10 0A LF 170 2A 234 4A J 298 6A j 11 0B VT 171 2B 235 4B K 299 6B k 12 0C FF 172 2C 236 4C L 300 6C l 13 0D CR 173 2D 237 4D M 301 6D m 14 0E SO 174 2E 238 4E N 302 6E n 15...

Страница 171: ...204 AC 268 CC 332 EC 141 8D 205 AD 269 CD 333 ED 142 8E 206 AE 270 CE 334 EE 143 8F 207 AF 271 CF 335 EF 144 90 208 B0 272 D0 336 F0 145 91 209 B1 273 D1 337 F1 146 92 210 B2 274 D2 338 F2 147 93 211...

Страница 172: ...ption is available for Code 39 Code 93 and Code 128 Code Page Standard Description 1 CP ISO646 2 Default ISO 2022 Automatic National Replacement Characters 3 CP Binary 82 ISO 2022 11 Swe Swedish Repla...

Страница 173: ......

Страница 174: ...Sample Symbols UPC A 0 123456 7890 Interleaved 2 of 5 Code 128 EAN 13 1234567890 Code 128 9 780330 290951 654 EAN 8 3210 5 456123 8 0 UPC E...

Страница 175: ...Sample Symbols Code 93 123456 9 Code 2 of 5 123456 Matrix 2 of 5 6543210 RSS 14 01 00123456789012 Code 39 Codabar BC321 A13579B...

Страница 176: ......

Страница 177: ......

Страница 178: ......

Страница 179: ...ogramming Chart A C Save B Discard F E D Note If you make an error while scanning the letters or digits before scanning Save scan Discard scan the correct letters or digits and Save 0 2 6 1 7 5 4 3 8...

Страница 180: ...Hand Held Products Inc 700 Visions Drive P O Box 208 Skaneateles Falls NY 13153 0208 5620 SM Rev C 3 05...