KE600 Inverter Parameter Description
91
Setting
value
Function
Description
13
Multi-step speed
terminal 2
14
Multi-step speed
terminal 3
15
Multi-step speed
terminal 4
16
ACC/DEC
time
selection terminal 1
It can select four types of ACC/DEC time though 4 statuses of the
two terminals. See attached table 2.
17
ACC/DEC
time
selection terminal 2
18
Main
frequency
source switching
Used to switch different frequency source.
According to the setting of frequency source selection (P0-07),
when setting switching between two frequency sources is frequency
source, it can achieve switching two frequency sources via this
terminal
19
UP and DOWN
setting clear
(terminal and
keyboard)
When the frequency reference is digital frequency reference, this
terminal can be used to clear the frequency value modified by
UP/DOWN and thus restore the reference frequency to the setting
value of P0-08.
20
Running command
switching terminal
When the command source (P0-02) is set to 1, it performs switching
between terminal control and keyboard control via this terminal.
When the command source (P0-02) is set to 2, it performs switching
between communication control and keyboard control via this
terminal.
21
ACC/DEC invalid
Protect the inverter from affecting by the external signals (except
stop command), and maintain the current frequency.
22
PID Pause
PID is invalid temporarily, and the inverter maintains the current
frequency output, no longer adjusts PID of frequency source.
23
PLC status reset
PLC pauses during the execution process. When it runs again, it
can restore to the initial status of simple PLC via this terminal.
24
Wobble frequency
pause
The inverter outputs the central frequency. Wobble frequency
function pauses.
25
Counter input
The input terminal of counting pulse.
26
Counter reset
Clear the counter status.
27
Length count input
Input terminal of length counting.
28
Length reset
Length clear
29
Torque control invalid
Torque control is invalid, the inverter adopts speed control mode.
30
PLUSE frequency
input (only valid for
HDI)
HDI is pulse input terminal.
31
Reserved
Reserved
32
DC braking command
When this terminal is valid, and the inverter directly switches to DC
braking status.
33
External fault normal
close input
After the external fault normal close signal is sent to the inverter, the
inverter reports fault E-15 and stops.
34
Frequency
modification enabled
If this function is valid, the inverter does not response to the
frequency changing, until this terminal is invalid
35
PID action direction
reverse
When this terminal is valid, PID action direction is the opposite of
value set by PA-03.
36
External stop
The inverter can be stopped by this terminal under keypad control,