KE600 Inverter Parameter Description
97
situation.
In difference applications, 100% of analog input corresponds to different nominal values. Refer to all the
application parts for details.
Several setting examples are shown in the following figures:
0V(0mA)
Corresponding setting
(frequency,torque)
AI
100%
10V(20mA)
-100%
10V(20mA)
100%
AI
0V(0mA)
Corresponding setting
(frequency,torque)
Figure 6-9 Corresponding Relationship between Analog Reference and Setting
P4-18
AI curve 2 minimum input
Factory default
0.00V
Setting range
0.00V ~ P4-20
P4-19
AI curve 2 minimum input corresponding
setting
Factory default
0.0%
Setting range
-100.00% ~ 100.0%
P4-20
AI curve 2 maximum input
Factory default
10.00V
Setting range
P4-18 ~ 10.00V
P4-21
AI curve 2 maximum input corresponding
setting
Factory default
100.0%
Setting range
-100.00% ~ 100.0%
P4-22
AI2 filter time
Factory default
0.10s
Setting range
0.00s ~ 10.00s