KE600 Inverter Parameter Description
121
Time (t)
Output frequency (
Hz)
Jump frequency 1
Jump frequency
2
Jump frequency amplitude
Jump frequency amplitude
Jump frequency amplitude
Jump frequency amplitude
Figure 6-17 Jump frequency during ACC/DEC diagram
P8-25
Acceleration time 1 and acceleration time 2
switching frequency point
Factory default
0.00Hz
Setting range
0.00Hz ~ P0-10 (maximum frequency)
P8-26
Deceleration time 1 and deceleration time 2
switching frequency point
Factory default
0.00Hz
Setting range
0.00Hz ~ P0-10 (maximum frequency)
This function is valid when don’t use DI terminal to switch ACC/DEC. Suitable for the inverter running
process, choose different ACC/DEC time according to the running frequency range (instead of through DI
terminals).
Dec time 2
DEC time 1
ACC time 1
ACC time
2
P8-26
Setting frequency (Hz)
P8-25
Output frequency (
Hz)
Time (t)
Figure 6-18 ACC/DEC time switching diagram
During ACC, if the running frequency is lower than P8-25, then select ACC time 2, if the running frequency
is higher than P8-25, then select ACC time 1.
During DEC, if the running frequency is higher than P8-26, then select DEC time 1, if the running frequency
is lower than P8-26, then select DEC time 2.
P8-27
Terminal jog priority
Factory default
0
Setting range
0: Invalid 1: Valid
It is used to set whether the priority of terminal jog function is the highest.
When terminal jog priority is valid, if terminal jog command appears when running, the inverter switches to