8.6
Thermal management connection
The fluid thermal management of the battery system is a two-line system, consisting of a cold supply
line and hot return line. Each battery module is connectect in parallel to the supply and return line,
an example is shown in figure 17 below.
For more information about the thermal management setup, e.g. pumps, heat exchanger, etc.,
please refer to the manual for that specific system.
Figure 17 - Fluid thermal management system connection example
Connection of the hose to the hose tail is explained in the steps below.
NOTICE:
The steps below only surve as a reference example. The actual assembly
instruction of the used material must always be taken into accout.
1.
Place the unpinched hose clamp over the hose end.
Figure 18 - Hose clamp in place before fitting