![MG Energy Systems MGRS12S4P176 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/mg-energy-systems/mgrs12s4p176/mgrs12s4p176_manual_1782743032.webp)
MG Energy Systems B.V. | Foeke Sjoerdswei 3 | 8914 BH Leeuwarden | The Netherlands
+31 (0)58 750 89 47 | [email protected] | www.mgenergysystems.eu
Innovation
in energy storage
Figure 15 - Propagation prevention system connection scheme
NOTICE:
Multiple battery modules can be connected in parallel to one Propagation
Protection System. It is recommended to install at least one PPS per six batteries.
It is mandatory to use at least one PPS per battery string.
7.6
Placement
Depending on the applicable class rules it might required that the battery room, i.e. the room where
the battery modules or placed in, is equipped with additional measures to mitigate the effects of
some risks.
If a fire exthinguishing system is required in the battery room the system using freshwater sprinklers
is preferred.