Fluid thermal management connections
Figure 7 shows the fluid themal management connections that is used for the battery module. It is a
hose tail for Ø 10 mm internal diameter hose made from nickel-plated brass.
Figure 7 - Fluid thermal mangagement in- and outlet connection
For connection to the fluid thermal management system a hose needs to be used with the following
requirements:
Ethylene glycol
resistant.
Inner diameter of Ø 10 mm.
Temperature operating window of 0 °C to 60 °C.
Exhaust connection
The function of the exhaust connection with pressure relief is to release gasses in case of a thermal
runaway event. The flammable and toxic gasses can be evicted from the module and released in a
safe area (outside).
The diameter of the exhaust is dimensioned to connect piping with an inner diameter of 80 mm.