80
Analysis. Typical tasks and solutions
5.17
Test traffic
Test data generating feature is to be used for the packet jitter measure-
ments. The analyzer supports generating the test data flow in two following
modes:
•
test data is generated and then jitter is measured at the same port (see
fig. 5.92);
•
test data is generated at one port, and then jitter is measured at another
one (see fig. 5.93); in this case, destination port could be a port at a
remote device (see fig. 5.94).
When generating the test data has been started, all settings in the menu
become inaccessible for editing.
NUT
jitter measuring
test data generating
port A(B)
loopback
Figure 5.92. Jitter measurements. Scheme 1
NUT
port B(A)
port A(B)
loopback
test data generating
jitter measuring
Figure 5.93. Jitter measurements. Scheme 2