FP4, FP4W
37
10 USER SCREENS
Switching between windows is possible with using: arrows , (displayed on the sides
of the screen) and the main menu icon
(displayed on the title bar). Arrows and the
main menu icon shows up after touching the screen.
10.1 Information about the device
This screen contains all the basic data concerning the device: model, ID, serial
number, firmware, IP address, COM (RS485) communication parameters and Modbus
address.
Fig. 10.1 A
n example view of the ‘Device Information’ window.
10.2 Single result window
The window is used for displaying a single result channel (only for enabled channels).
The window displays all data concerning a selected measurement channel:
channel description,
current value,
a unit,
values and units of totalizers 1 and 2 (if totalizers are active),
values of timers (operating time of totalizers 1 and 2, if totalizers are active),
channel number.
In the top part of the screen, there is a channel description entered by the user. Below,
the current value of the channel is displayed together with the unit declared by the user. At
the bottom part of the screen there are values of totalizers (
Σ1, Σ2) or timers (T1, T2) with
their units (switching with the buttons
Totalizers
/
Timers
).
Click on the
Reset
button to reset the value of totalizers and timers (for totalizers
marked as Resettable). After pressing, the window for reset parameters shows up (only for
logged in user). It is possible to zeroing values for a single channel or for all active
channels.
The channel number is displayed in the bottom right corner of the screen.