EasyGrid Base User Guide v1.0   

 

 

 

 

 

EasyGrid Base 

User Guide 

MAN-00112 

 

 

 
 

Summary of Contents for EasyGrid

Page 1: ...EasyGrid Base User Guide v1 0 EasyGrid Base User Guide MAN 00112 ...

Page 2: ...om its use No license is granted by implication or otherwise under any patent rights of FISO FISO s Commerce and Government Entities CAGE code under the North Atlantic Treaty Organization NATO is L0294 The information contained in this publication is subject to change without notice 2018 FISO Technologies Inc Words that FISO considers trademarks have been identified as such However neither the pre...

Page 3: ...ators Explained 14 4 9 Analog Outputs 15 4 10 Connection USB 15 4 11 Connection Ethernet 16 4 12 Connection RS 485 RS 422 17 4 13 RS 485 RS 422 Network Recommendations 18 4 14 Physical Dimensions 19 5 Wiring Information 20 5 1 General 20 5 2 Power 20 5 3 Analog output 21 5 4 Analog Output Scale 22 5 5 System Relay 23 5 6 RS 485 RS 422 24 6 Nortech Client II Software 26 7 Troubleshooting 27 7 1 Sol...

Page 4: ...e European Union Directive and Standards Tests were performed externally at an independent accredited laboratory This guarantees the unerring objectivity and authoritative compliance of all test results Use of shielded remote I O cables with properly grounded shields and metal connectors is recommended in order to reduce radio frequency interference that may emanate from these cables Shielded I O ...

Page 5: ... IEC 60255 22 2 20081 Electrostatic discharge immunity 8kV Contact Discharge 15kV Air Discharge IEC 61000 4 3 2006 A1 2007 A2 2010 IEC 60255 22 3 20071 Radiated electromagnetic field immunity 10V m 80 3000MHz Spot frequencies 80MHz 160MHz 380MHz 450MHz 900MHz 1850MHz 2150MHz 10V m IEC 61000 4 4 2012 IEC 60255 22 4 20081 Electrical fast transient immunity EFT 4kV Power Lines 4kV I O IEEE C37 90 1 2...

Page 6: ...d on or after the Date of Issue of this declaration of Conformity do not contain any of the restricted substances in concentration applications not permitted by the RoHS Directive Supplementary information FCC Part 15 2018 subpart B Class A This product meet the EMC requirement of the United States ICES 003 2016 Class A This product meet the EMC requirement of the Canada IPC CC 830 MIL I 46058C En...

Page 7: ...ceed unless you understand and meet the required conditions WARNING Indicates a potentially hazardous situation that if not avoided may result in minor or moderate injury Do not proceed unless you understand and meet the required conditions CAUTION Indicates a potentially hazardous situation that if not avoided may result in component damage Do not proceed unless you understand and meet the requir...

Page 8: ...SE IN LIFE SUPPORT OR CRITICAL APPLICATIONS In no case will FISO be liable to the buyer or to any third parties for any consequential damage or indirect damage which is caused by product failure malfunction or any other problem When using any electrical appliance basic safety precautions should be followed including the following FISO recommends using SEN PS EXT power supply with your monitor and ...

Page 9: ...the carrier If the shipping carton is not damaged carefully remove and identify all of the components listed below Contact FISO or your local representative if any of the components are missing We recommend you save the shipping carton for future storage or transportation The EasyGrid Base package should include the following components EasyGrid Base unit USB cable micro ST Connector One Click Cle...

Page 10: ...nd 1x optional Ethernet communication port Standard supported serial communication protocol is MODBUS Optional supported Ethernet communication protocols are IEC 61850 IEC 60870 5 104 DNP3 and TCP IP MODBUS 4 2 Front Panel Overview EasyGrid Base displays a very slim and simple front panel showing the following status lights On Top One Click Fiber Optic cleaner receptacle Don t ever look for it any...

Page 11: ...t COM port CAT6 or FO a Usual network Link and Activity LED lights present D USB connection micro connector a Used in correlation with the Nortech Client II software E RS 485 RS 422 connection port a DIP switch options include resistance load selection F Relay System a To trigger an alarm or a system in a Normally Open or Closed fashion G Analog Outputs a 1 per channel b Up to 12 available c Signa...

Page 12: ...to the input complies with technical specifications No other voltage level or range is accepted 4 6 Optical Connectors There can be up to 12 optical channels on each EasyGrid Base Each channel is designed to be connected with a fibre Optic extension an EasyThrough and a Fiber Optic sensor CAUTION Use care in handling fiber optic connectors Always clean the fiber tip prior to insertion into the con...

Page 13: ... The cap s is designed to help you keep the connector s clean preventing the dust from accumulating inside when not in use The cap s just need to be pulled off to uncover the desired optical connector s and left dandling when a sensor is connected It is recommended to always put the protective caps back on when a channel is not in use and no sensor is connected ...

Page 14: ...BER Blink Activity over RS 485 RS 422 communication port LAN AMBER Blink Activity over LAN communication port optional Channel s GREEN RED Channel is enabled AND a sensor is detected Channel is enabled AND a sensor is NOT detected Side Panel LEDs The only two LEDs present on that panel are from the optional Ethernet communication port LED Name Color Indication Activity GREEN Network cable is conne...

Page 15: ...ted when connecting analog outputs For a run of 100 m or less recommended gage is 24 AWG or greater The longer the run the smaller the recommended gage will be Recommendations call for shielded wire or for installation in a metal conduit Please refer to Channel Setup and Analog Output Scale section of the Nortech Client II User Guide for detailed information 4 10 Connection USB The USB configurati...

Page 16: ...her Copper or Fiber Optic to connect to it Configuring all IP settings can be achieved using the Nortech Client II while being directly connected into the COM port The configuration connection can be achieved in one of the 2 following configurations Option 1 Option 2 RJ45 Ethernet Option FO Ethernet Option ...

Page 17: ...EL MODE RS 422 RS 485 B RX DATA A RX DATA B TX N A A TX N A GND GROUND GROUND A set of dip switches is used to configure the port They are located at the left of the terminal block DIP switches positioned towards the TOP are at the ON position DIP switches positioned towards the BOTTOM are at the OFF position LABEL DIP switch position RS 485 RS 422 422 485 ON OFF 422 485 ON OFF OFF EOL ON OFF Adds...

Page 18: ...nknown voltage on these lines RS 485 BUS floating Leaving the RS 485 BUS floating may result in conditioner communication failure You must identify the host device on the RS 485 network and then proceed with its RS 485 BUS line biasing Two termination resistors must be installed and have the same characteristic impedance value as the twisted wire used on the RS 485 network RS 485 network terminati...

Page 19: ...EasyGrid Base User Guide v1 0 19 4 14 Physical Dimensions ...

Page 20: ...2AWG 0 33mm2 Terminal block Part Manufacturer Recommended screwdriver blade Recommended torque Recommended strip length Wire size range Power 1850851 Phoenix Contact 0 4 X 2 5mm 0 23Nm 2lb in 9mm 0 33 1 5mm RS 485 RS 422 1850880 Phoenix Contact 0 4 X 2 5mm 0 23Nm 2lb in 9mm 0 14 1 5mm2 System Relay 1850864 Phoenix Contact 0 4 X 2 5mm 0 23Nm 2lb in 9mm 0 14 1 5mm 2 Analog Outputs 1850958 Phoenix Co...

Page 21: ...A outputs negative terminals are internally connected to the power supply ground and that ground is internally connected to the system GND at the M5 GND stud bottom left of the EasyGrid Base case The cables shields must be grounded at only one end we recommend to connect them to the EasyGrid Base M5 GND stud In order to avoid ground loop errors the EasyGrid Base 4 20mA outputs shall be connected t...

Page 22: ...e formulas for the Analog Output The Analog Output is represented by a straight line equation of this form Formula Where Parameter Symbol Analog Output Min C AnaOutMin C Analog Output Max C AnaOutMax C Scale factor C mA m Current Output I mA x Temperature output T y All channels share the same original factory set configuration the scale factor is 16 56 C mA This setting results in the 0 C offset ...

Page 23: ...zed Normally Open When powering up relay will be energized and in case of power outage power supply wiring cut off the relay will be de energized The following conditions will generate an alarm making the System Relay trigger Power failure If a channel is at fault If the internal software is at fault If the system s hardware is at fault At power up the EasyGrid Base system relay is in alarm until ...

Page 24: ...polarising the link in one place You could use the integrated pull up and pull down resistors of the EasyGrid Base To do so place the Pull Up and the Pull Down dip switch to the top A and B Circuit Designators The A and B circuit designators are often a source of confusion To determine which terminal is A and which is B set the line to the Idle or Off state Connect a multi meter on the volts range...

Page 25: ...EasyGrid Base User Guide v1 0 25 RS 485 Wiring ...

Page 26: ...EasyGrid Base User Guide v1 0 26 6 Nortech Client II Software Please refer to the Nortech Client II software guide available here http www fiso com 2DScans ...

Page 27: ...there is something wrong with the channel Symptom Possible Cause Possible Solution Channel LED is RED Channel is enabled and but there is no sensor connected Verify that you have in fact connected the sensor into that specific channel Dirty connector Using a fiber optic cleaner like the One Click Cleaner provided with the unit clean all connector ends of both the sensor and the channel No signal o...

Page 28: ...oblems Contaminated or Dirty connection Over bent cable along the sensor cable routing Broken Sensor or Extension Cable Damage Sensor Tip Don t forget all connections should ALWAYS be cleaned first using appropriate cleaning tool like a One Click Cleaner 7 3 Sensor s Light levels The sensor light value gives an indication of the sensor health Light Levels Sensor connected directly into the monitor...

Page 29: ...Protection Fuse Should it become necessary to verify or change the 1A protection fuse proceed as following 1 First remove power from the unit 2 Using a flat head screw driver or a coin unlock the fuse cap by doing a left half turn 3 The fuse cap is spring loaded and will self pop out when totally unscrewed as displayed 4 You can then verify the state of the fuse and replace it if necessary 5 You c...

Page 30: ... been removed The case has been opened The equipment serial number has been altered erased or removed The equipment has been misused neglected or damaged by accident 8 2 Liability FISO shall not be liable for damages resulting from the use of the purchased product nor shall be responsible for any failure in the performance of other items to which the purchased product is connected or the operation...

Page 31: ... packing material when shipping Keep the unit out of direct sunlight Avoid unnecessary shock and vibration 8 6 FISO Service Center If your product requires servicing contact your local FISO supplier or FISO Headquarters FISO Headquarters Service Center 500 St Jean Baptiste Avenue Suite 195 Quebec City Quebec CANADA G2E 5R9 Telephone 418 688 8065 Fax 418 688 8067 Email support FISO com 8 7 Product ...