3.2. Remote control commands
719 S Titrino
92
Selection of the values from Assembly for the output in the set time interval
(see 3.2.2.82):
.CyclNo: Cycle number of the potential measurement. Together with the
cycle time (3.2.2.81), a time frame can be set up.
The cycle number is set to 0 on switching on the instrument and it
is always incremented as long as the instrument remains
switched on.
.V: Volume
.Meas:
Measured value associated to the cycle number.
The unit "assembly" must be preset (see 3.2.2.83).
3.2.2.85. Se
tup
.S
endMeas
.T
itrator
.C
yclNo ON,
OFF
Se
tup
.S
endMeas
.T
itrator
.V
ON,
OFF
Se
tup
.S
endMeas
.T
itrator
.M
eas ON,
OFF
Se
tup
.S
endMeas
.T
itrator
.d
Vdt ON,
OFF
Se
tup
.S
endMeas
.T
itrator
.dM
easdt ON,
OFF
Se
tup
.S
endMeas
.T
itrator
.dMeasdV
ON,
OFF
Selection of the values from the titrator which are sent in the set time interval
(see 3.2.2.82, formats see 3.2.2.68):
.CyclNo: Cycle number. Together with the cycle time (3.2.2.71), a time
frame can be set up. The other data belong to the corresponding
cycle number. The cycle number is set to 0 at the start of a
method and it is incremented until the end of the method.
.V: Volume.
.Meas: Measuring
value
.dVdt:
associated volume drift.
.dMeasdt: associated measured value drift.
.dMeasdV: associated 1st derivative of the titration curve.
The unit "titrator" must be preset (see 3.2.2.83).
3.2.2.86. Se
tup
.A
utoInfo
.S
tatus
ON
, OFF
Se
tup
.A
utoInfo
.P
ON,
OFF
Se
tup
.A
utoInfo
.T.R
ON,
OFF
Se
tup
.A
utoInfo
.T.G
ON,
OFF
Se
tup
.A
utoInfo
.T.GC
ON,
OFF
Se
tup
.A
utoInfo
.T.S
ON,
OFF
Se
tup
.A
utoInfo
.T.B
ON,
OFF
Se
tup
.A
utoInfo
.T.F
ON,
OFF
Se
tup
.A
utoInfo
.T.E
ON,
OFF
Se
tup.
A
utoInfo
.T.H
ON,
OFF
Se
tup
.A
utoInfo
.T.C
ON,
OFF
Se
tup.
A
utoInfo
.T.O
ON,
OFF
Se
tup
.A
utoInfo
.T.N
ON,
OFF
Se
tup
.A
utoInfo
.T.Re
ON,
OFF
Se
tup
.A
utoInfo
.T.Si
ON,
OFF
Se
tup
.A
utoInfo
.T.M
ON,
OFF
Se
tup
.A
utoInfo
.T.EP
ON,
OFF
Se
tup
.A
utoInfo
.T.RC
ON,
OFF
Se
tup
.A
utoInfo
.I
ON,
OFF
Se
tup
.A
utoInfo
.O
ON,
OFF
Содержание Titrino 719 S
Страница 2: ......
Страница 6: ...1 2 Controls and parts 719 S Titrino 2 1 2 Controls and parts Front view of instrument...
Страница 8: ...1 2 Controls and parts 719 S Titrino 4 Rear view of instrument...
Страница 58: ......
Страница 106: ......
Страница 135: ...6 2 Pin assignment of the Remote socket 719 S Titrino 131 6 2 1 Lines of the Remote socket during the titration...