4
Assembly manual FS2 EI60/120 Version 11, jan.. 2021
2. Introduction
The fire-retardant roller screen is an entry delay door and is not suitable for daily use.
This fire-retardant roller screen is intended only to separate linked space in case of fire or smoke
development, this in connection with the so-called fire penetration towards adjacent spaces. The fire-
retardant roller screen could be part of a fire-retardant system.
This could be a fire alarm system.
The fire-retardant roller screen will be operated only by a technician of the installation company. The user
himself does not need to operate the fire-retardant roller screen.
Technical specifications:
Below there is a list of the technical specifications of a fire-retardant roller screen..
Fire-retardant roller screen is manufactured from incombustible material:
FS EI60-EW120
Material assembly
Sendzimir galvanized steel.
Locomotor system
Consisting of: 2 guides to which 2 consoles have been assembled, in which
bearings and supports were applied containing the tube with the fire-
retardant roller screen rotating on top. A cross bar ensures that the canvas
runs smoothly into the guides, the entire assembly is finished by use of a
casing. The related components form a self-supporting structure.
Side guiding
120 mm wide and 80 mm deep.
Top roller construction
Fitted with casing against flash-back.
Motor
Standard failsafe tube motor 230 [V]
Controls
All types that could be required by the fire brigade and/or government.
Fire resistant
EI60 / EW120
Standards
EN 16034; EN 1634-1:2014+A1:2018 (European standards)
Certificate
Report number: 2434-CPR-0160
Options Emergency battery, smoke/temperature detector, signal transmitters, etc.
Assembly
Executable in RAL color.
Dimensions
Maximum dimension 10.000 x 8.000 mm (Br x Hg )
according EXAP EN 15269-11:2018+C1:2019