56
12. TROUBLESHOOTING
12.1 TROUBLESHOOTING CHART
PROBLEM
CAUSE
SOLUTION
Engine will not start.
No fuel.
Fill the fuel tank.
Low engine oil.
Fill the crankcase with oil.
Cold engine.
Open choke.
Ignition key switch off.
Turn ignition key switch on.
Battery dead.
Recharge or replace battery.
Engine problem.
Refer to engine manual.
Conveyor belt will not start.
No power.
Start engine and increase speed above
1400 RPM.
Drive motor coupling.
Repair or replace coupling.
Belt tension.
Increase belt tension.
No hydraulic oil.
Check oil level.
Electrical or hydraulic functions
are not working properly.
Transmitter power is OFF.
Turn Power ON.
Receiver power is OFF.
Turn Power ON.
Battery cable or battery.
Check battery cable and make sure battery
is fully charged.
Error in the control system.
Check LED Error Code light.
Improper ground.
Check for proper grounding electrical
circuit.
Hydraulic valve or motor.
Ensure hydraulic pump is working properly
andhydraulictankisfilledwithoil.
Intermittent function.
Check receiver antenna for damage and
proper connection.
Loose connector at the valve coil.
Weigh-Tronix display is not work-
ing when power is ON.
No input power.
Inspect the power cable for possible
damage.
Check the wiring connections for corrosion,
bent pins, or wire damage.
Incorrect Voltage.
The required Voltage is 10 to 17 Volts
with a negative ground. If the Voltage
is between 9 and 10 Volts, the indicator
will alternate between LOW.BAT and the
appropriate mode.
Dead battery.
Make sure the seed tenders 12 VDC
battery is fully charged and the output is 12
Volts.
Internal fuse.
Replace the 3.15 Amp fuse on the PC
board. Replace the fuse with Avery Weigh-
Tronixstylefuseorequivalent(AWTP/N
48561‑0190).Thefuseissoldereddirectly
to the main board and should be replaced
byacertifiedscaletechnician.
Check for incorrect connection to
the battery.
Connect BLACK wire to Ground and
WHITE wire to +12 VDC.
Weigh-Tronix display turns OFF
automatically.
Insufficientpower.
The indicator will automatically turn OFF if
the Voltage drops below 9 Volts for more
thanfiveseconds.
Содержание SEED EXPRESS 240 RT
Страница 1: ...FOR OWNERS AND OPERATORS OF THE 240 RT 375 RT SEED EXPRESS ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 21: ...21 6 WARNING Fall Hazard 19939 7 WARNING Hot Surface 20088 8 WARNING Missing Shield 19937 ...
Страница 22: ...22 4 SPECIFICATIONS 4 1 OVERALL 240RT SEED TENDER SPECIFICATIONS 6 AND 8 CONVEYORS ...
Страница 23: ...23 4 2 OVERALL 375RT SEED TENDER SPECIFICATIONS 6 AND 8 CONVEYORS ...
Страница 60: ...60 14 1 240RT SEED TENDER ...
Страница 63: ...63 14 1 2 Turret Detail Continued 240RT 74 41 37 32 31 1 45 65 38 52 31 22 26 26 42 64 76 25 33 ...
Страница 64: ...64 14 1 3 Side View Detail 240RT 82 69 6 44 77 30 31 35 16 78 4 5 78 75 75 56 7 7 53 76 89 ...
Страница 66: ...66 14 1 5 Slide Gate Detail 240RT 49 61 36 66 29 86 85 18 ...
Страница 69: ...69 NOTES ...
Страница 70: ...70 14 2 375RT SEED TENDER ...
Страница 73: ...73 14 2 2 Turret Detail Continued 375RT 7 12 19 13 64 10 11 36 6 23 9 16 48 65 13 46 86 86 ...
Страница 74: ...74 14 2 3 Side View Detail 375RT 28 37 60 58 45 59 29 13 13 29 61 21 22 74 74 62 63 25 24 24 56 85 1 89 ...
Страница 76: ...76 14 2 5 Slide Gate Detail 375RT 4 35 51 22 21 3 85 ...
Страница 79: ...79 NOTES ...
Страница 80: ...80 14 3 CONVEYOR 6 80624 14 3 1 Pan Detail 14 3 2 Tube Detail 14 3 3 Discharge Hood Detail ...
Страница 83: ...83 14 3 2 Tube Detail 21 13 12 13 13 37 1 35 1 36 1 13 29 30 13 83 ...
Страница 85: ...85 NOTES ...
Страница 86: ...86 14 4 CONVEYOR 8 80622 14 4 1 Pan Detail 14 4 2 Tube Detail 14 4 3 Discharge Hood Detail ...
Страница 88: ...88 14 4 1 Pan Detail 28 4 27 17 3 15 14 47 13 10 1 36 49 26 25 22 19 19 32 11 1 8 1 9 41 12 29 48 9 50 27 4 ...
Страница 89: ...89 14 4 2 Tube Detail 37 40 39 24 24 22 37 38 37 2 58 59 24 24 24 ...
Страница 92: ...92 14 5 1 Bumper Hitch Trailer A B C 5 6 11 22 21 10 23 24 1 5 19 13 20 9 7 15 7 4 4 ...
Страница 93: ...93 14 5 2 Bumper Hitch Trailer D 12 18 17 2 8 3 16 2 25 18 17 12 26 14 ...
Страница 95: ......