Section 5 - Maintenance
Page 80
90-8M0069751
eng
APRIL 2012
7. Place the remote control in neutral, idle speed position and start the engine.
NOTICE
Operating the engine out of the water at high speeds creates suction, which can collapse the water supply hose and overheat
the engine. Do not operate the engine above 1400 RPM out of the water and without sufficient cooling water supply.
8. Operate the engine with the sterndrive in neutral at a fast idle between 600 to 1400 RPM for about 10 minutes or until
discharge water is clear.
9. Monitor the water temperature gauge to ensure that the engine is operating normally.
10. Slowly return the throttle to the idle speed position.
11. Stop the engine.
12. Shut off the water supplies.
13. Remove the sterndrive flushing attachments.
14. Remove any adaptors used and reconnect the seawater hoses.
Engine Seawater Pump Inspection
IMPORTANT: Mercury strongly recommends that this service be performed by a Mercury Diesel authorized repair facility.
Remove and inspect the engine seawater pump at the interval specified in the
Maintenance Schedule
. See your Mercury
Diesel authorized repair facility.
Alpha Sterndrive Seawater Pump Inspection
IMPORTANT: Mercury Diesel strongly recommends that this service be performed by a Mercury Diesel authorized repair
facility.
Remove and inspect the Alpha sterndrive seawater pump at the interval specified in the
Maintenance Schedule
. See your
Mercury Diesel authorized repair facility.
Replacing the Engine Coolant
Draining the Closed‑Cooling System
IMPORTANT: Due to the complex nature of this service Mercury Diesel strongly recommends that this service be performed by
a Mercury Diesel authorized repair facility.
NOTICE
Discharge of oil, coolant, or other engine/drive fluids into the environment is restricted by law. Use caution not to spill oil,
coolant, or other fluids into the environment when using or servicing your boat. Be aware of the local restrictions governing
the disposal or recycling of waste, and contain and dispose of fluids as required.
NOTE: For instructions on draining the seawater section, refer to
Draining the Seawater System
in this section.
IMPORTANT: Observe the following points.
•
Ensure that the engine is as level as possible to promote complete draining of the cooling system.
•
The closed‑cooling section must be filled year‑round with the required coolant. If the engine will be exposed to freezing
temperatures, ensure that the closed‑cooling section is filled with a solution of low silicate ethylene glycol antifreeze and
deionized, purified water properly mixed to protect the engine to the lowest temperature to which it will be exposed.
•
Do not use propylene glycol antifreeze in the closed‑cooling section of the engine.
!
CAUTION
A sudden loss of pressure can cause hot coolant to boil and discharge violently resulting in serious injury from burns. Allow
the engine to cool down before removing the coolant pressure cap.
1. Allow the engine to cool.
2. Remove the pressure cap from the expansion tank and coolant reservoir.
3. Remove the fuel filter for access to the engine coolant drain plug. Refer to
Water–Separating Fuel Filter
.
Содержание Sterndrive QSD 2.0
Страница 4: ......
Страница 8: ...Page iv 90 8M0069751 eng APRIL 2012...
Страница 14: ...Section 1 Warranty Notes Page 6 90 8M0069751 eng APRIL 2012...
Страница 30: ...Section 2 Getting to Know Your Power Package Notes Page 22 90 8M0069751 eng APRIL 2012...
Страница 54: ...Section 5 Maintenance Page 46 90 8M0069751 eng APRIL 2012 Date Maintenance Performed Engine Hours...
Страница 122: ...Section 6 Storage Notes Page 114 90 8M0069751 eng APRIL 2012...