TECHNICAL CHARACTERISTICS
6-1
MA-5184-ENG
PUR LC/MC ADHESIVE MELTER
MICRON
PUR LC
MICRON
PUR MC
Tank capacity
5,15 liters
37,4 liters
Pumping rate
simple pump
double pump (per output)
1, 2.5, 4, 8 cc/rev
(*)
2x0.93, 2x1.86, 2x3.71, 2x4.8 cc/rev
(*)
1, 2.5, 4, 8 cc/rev
(*)
2x0.93, 2x1.86, 2x3.71, 2x4.8 cc/rev
(*)
Melting rate
2 kg/h (*)
20 kg/h (*)
Number of outputs
2, 4 ó 6 with one pump
2, 4 ó 6 with one pump
Temperature range
40 a 200°C (104 a 392°F)
40 a 200°C (104 a 392°F)
Temperature control
RTD ±0.5°C (±1°F)
Pt-100, Ni-120 o NTC-R
RTD ±0.5°C (±1°F)
Pt-100, Ni-120 o NTC-R
Max. working pressure (at 6 bar)
80 bar (1160 psi)
80 bar (1160 psi)
Max. installation power
with a simple pump/2 outputs
with a simple pump/4 outputs
with a simple pump/6 outputs
with two simple pumps/2 outputs
with two simple pumps/4 outputs
1 x 8,5KW / 3 x 4,5KW
1 x 12,1KW / 3 x 4,5KW
1 x 15,6KW / 3 x 5,8KW
1 x 9,8KW / 3 x 4,5KW
1 x 13,4KW / 3 x 4,6KW
1 x 10,0KW / 3 x 4,3KW
1 x 13,5KW / 3 x 6,1KW
1 x 17,2KW / 3 x 7,9KW
1 x 11,3KW / 3 x 5,3KW
1 x 14,9KW / 3 x 7,1KW
External functions
Inputs
Outputs
Unit On-Off / Standby On-Off /
Activity Control / Pumping On-Off /
Communications On-Off / Electrical
Outputs Inhibition.
Standby / Zones Temperature OK /
Machine Ready / Running / Alarm /
Level / No Level
Unit On-Off / Standby On-Off /
Activity Control / Pumping On-Off /
Communications On-Off / Electrical
Outputs Inhibition.
Standby / Zones Temperature OK /
Machine Ready / Running / Alarm /
Level / No Level
Electrical requirements
LN ~ 230V 50Hz + PE
3N ~ 400V 50Hz + PE
LN ~ 230V 50Hz + PE
3N ~ 400V 50Hz + PE
Ambient temperature
0 a 40°C
0 a 40°C
Dimension (LxAxH)
730 x 420 x 630 mm
730 x 420 x 910 mm (lid open)
740 x 520 x 870 mm
740 x 520 x 1215 mm (lid open)
Weight
with one pump
105 kg (empty)
147 kg (empty)
6. TECHNICAL CHARACTERISTICS
Generals
Содержание Micron PUR LC
Страница 1: ...ADHESIVE MELTER MICRON PUR LC MC INSTRUCTIONS MANUAL MA 5184 GBR 010920 GLUING SOLUTIONS ...
Страница 20: ...This page is intentionally left blank MELER GLUING SOLUTIONS 2 8 INTRODUCTION ...
Страница 34: ...MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Страница 49: ...MELTER OPERATION 4 15 MA 5184 ENG MICRON PUR LC MC ADHESIVE MELTER This page is intentionally left blank ...
Страница 84: ...MELER GLUING SOLUTIONS 5 10 MAINTENANCE Esta página no contiene texto ...
Страница 90: ...MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 94: ...MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...