INSTALLATION
3-7
MA-5184-ENG
PUR LC/MC ADHESIVE MELTER
External I/O connections
The input and output (Input/Output) signals enable the melter to communicate
with the main machine simply and directly. Six I/O different signals can be
used, depending on the options installed on the unit. Function of these signals
can be selected by the user
The signals that can be used to communicate with the main machine are as
follows:
(1) See point ‘4 Use / Settings Menu / Configuration of input and output signals’.
Some inputs will not be shown on the menu, depending on which options are installed in the
unit.
(2) See point ‘4 Use / Heating Menu / Auto Standby - OFF’.
(3) See point ‘4 Use / Settings Menu / Additional Settings’.
(4) See point ‘4 Use / Heating Menu / Inhibitions’
(5) Connectors available according to options installed on the equipment..
X9
X21
DI3
Type
(1)
Description
Terminal/Connector
Input
External ON/OFF
A closed contact switches the unit on; an open contact turns it off.
Terminal
XDI1.1 / XDI1.2
XDI2.1 / XDI2.2
------
Connector on
HMI card
(5)
DI3
Under maintenance external ON/OFF
A closed contact activates the ‘Under maintenance’ function; an open contact
deactivates it and the unit returns to the status indicated by the unit’s other
signals.
Pumping external OFF
A closed contact activates pumping (if the required conditions are met); an open
contact deactivates it.
Activity (Auto Standby - OFF)
Contact for the activity control signal, to switch the unit to Standby and off
mode
(2)
.
ON/OFF communications
A closed contact activates the communications (Modbus/Profibus); an open
contact deactivates them. Signals must be enabled in the unit
(3)
.
Inhibition of zones
Zone inhibition control inputs. The unit has 8 contacts to inhibit 8 groups of
programmable zones
(4)
. When the contact is closed, the respective group is
inhibited (off); when the contact is open, the inhibition of that group is disabled
(activated).
Temperature Control
Board
X21 (Signals 1 to 4)
X9 (Signals 5 to 8)
Содержание Micron PUR LC
Страница 1: ...ADHESIVE MELTER MICRON PUR LC MC INSTRUCTIONS MANUAL MA 5184 GBR 010920 GLUING SOLUTIONS ...
Страница 20: ...This page is intentionally left blank MELER GLUING SOLUTIONS 2 8 INTRODUCTION ...
Страница 34: ...MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Страница 49: ...MELTER OPERATION 4 15 MA 5184 ENG MICRON PUR LC MC ADHESIVE MELTER This page is intentionally left blank ...
Страница 84: ...MELER GLUING SOLUTIONS 5 10 MAINTENANCE Esta página no contiene texto ...
Страница 90: ...MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 94: ...MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...