INSTALLATION
3-13
MA-5184-ENG
PUR LC/MC ADHESIVE MELTER
External signals of pumping control
The signals that can be used for pumping control externally are:
Connection of externar singnals for pumping control
Warning:
Risk of electric shock. Carelessness may cause injury or death
1. Disconnect the unit’s power.
2. Open the front door of the electric cabinet by giving the fastening
screw a 1/4 turn.
3. Run the signal cable (max. Ø14 mm) through the bushing at the rear
of the unit (P) and attach it to the interior fitting, making sure the
cable reaches the corresponding terminals.
4. Connect the two cable wires to the corresponding terminal. The
polarity of the connection must be correct:
5. Make sure that the cables are properly secured by the terminal’s
screws.
6. Check that the cable is correctly connected and that its passage
through the electric cabinet presents no risk of jamming, being cut
or any other accidental damage.
7. To assign the function to be performed by the connected signal, see
point ‘4 Operation / Pumping control menu’ y ‘4 Operation / Modes
of operation’.
P
Type
Description
Terminal
Input
External speed control pump 1 / pump 2
Contact for the external regulation of the pumping speed according to a
programmed ramp.
Pump 1: XV1.1 / XV1.2
Pump 2: XV2.1 / XV2.2
External pump control pump 1 / pump 2
Contact for external activation and deactivation of the pump. The closed
contact activates the pump and the open contact deactivates it.
Pump 1: XP1.1 / XP1.2
Pump 2: XP2.1 / XP2.2
Output
Drive error pump 1 / pump 2
Contact indicating that the pump drive is in error mode.
Pump 1: XE1.1 / XE1.2
Pump 2: XE2.1 / XE2.2
Borne
Pump 1
Polarity
Borne
Pump 2
Polarity
XV1.1
+ ISOLATED 0-10V
XV2.1
+ ISOLATED 0-10V
XV1.2
GND
XV2.2
GND
XP1.1
+24 VDC 400mA
XP2.1
+24 VDC 400mA
XP1.2
IN
XP2.2
IN
XE1.1
OUT+ 24 VDC 100mA
XE2.1
OUT+ 24 VDC 100mA
XE1.2
OUT- 24 VDC 100mA
XE2.2
OUT- 24 VDC 100mA
Содержание Micron PUR LC
Страница 1: ...ADHESIVE MELTER MICRON PUR LC MC INSTRUCTIONS MANUAL MA 5184 GBR 010920 GLUING SOLUTIONS ...
Страница 20: ...This page is intentionally left blank MELER GLUING SOLUTIONS 2 8 INTRODUCTION ...
Страница 34: ...MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Страница 49: ...MELTER OPERATION 4 15 MA 5184 ENG MICRON PUR LC MC ADHESIVE MELTER This page is intentionally left blank ...
Страница 84: ...MELER GLUING SOLUTIONS 5 10 MAINTENANCE Esta página no contiene texto ...
Страница 90: ...MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 94: ...MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...