Mounting the equipment
For mounting the equipments set the base in the desired location using the
indicated holes M8 screws. To move the equipment more comfortably use the
eyebolts included for this purpose.
Warning:
Make sure that the bench where the base plate is fastened is level,
free from vibrations and is able to support the weight of the equipment in
addition to the full tank load.
Besides, these melters may come with wheels (optional) so they can be easily
moved and located near to the main machine.
The four wheels turn 360º, and two are equipped with brakes. To move the
unit, unlock the two wheels by lifting the lever.
Slide the unit to its final position. Lock the wheels once again, lowering the
levers.
Electrical power connection
‘’ series melters/applicators are designed to be connected to the
electrical power supply in three possible ways, depending on the power of
different elements connected:
• 1-phase 230 VAC with neutral
• 3-phases 240/400 VAC with neutral
A good ground connection is required in all cases.
Los valores de consumo, según equipo fusor y configuración de salidas, son
los que se ven en la tabla adjunta. Para este cálculo se ha tenido en cuenta
sólo el caso de llevar bomba simple, para consumos con bomba doble,
consultar. Debido a la conexión de alta potencia, Meler recomienda conectar
trifásico 400/230 VAC con neutro.
Warning:
Risk of electrical shock. Carelessness may cause injury or death.
(1)
La
máxima corriente admisible
de conexión es de 27 A por fase. En la
tabla se indican las corrientes máximas en el caso de utilizar la máxima
potencia posible. Estimar en cada caso la potencia que va a instalarse para
elegir la conexión idónea.
UNIT
No. OUTPUTS
1 Phases
(1)
3 Phases
230 VAC
400 VAC Y
1
Pump
2
Pump
1
Pump
2
Pump
PUR
LC
2
27 A (!)
27 A (!)
12,80
14,17
4
27 A (!)
27 A (!)
19,76
21,13
6
27 A (!)
27 A (!)
25,09
25,09
PUR
MC
2
-
-
22,80
24,17
4
-
-
27 A (!)
27 A (!)
6
-
-
27 A (!)
27 A (!)
Maximum connection power for each hose-applicator pair: 1,800W
Содержание Micron PUR LC
Страница 1: ...ADHESIVE MELTER MICRON PUR LC MC INSTRUCTIONS MANUAL MA 5184 GBR 010920 GLUING SOLUTIONS ...
Страница 20: ...This page is intentionally left blank MELER GLUING SOLUTIONS 2 8 INTRODUCTION ...
Страница 34: ...MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Страница 49: ...MELTER OPERATION 4 15 MA 5184 ENG MICRON PUR LC MC ADHESIVE MELTER This page is intentionally left blank ...
Страница 84: ...MELER GLUING SOLUTIONS 5 10 MAINTENANCE Esta página no contiene texto ...
Страница 90: ...MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 94: ...MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...